7 Product-specific CAN objects XN300 slice modules
7.25 XN-322-1CNT-8DIO
Gateway XN-312-GW-CAN 06/16 MN050003-EN
www.eaton.eu
343
7.25.14 Encoder Status SDO (Object 0x40F7)
Object 0x30F4 transmits the counter's status signals as an SDO.
Design of the data bytes:
Byte 0:
Design of the data bytes:
Byte 0:
Sub-Index 1
≦
n
≦
254
Bit 5 will be automatically reset after the register is read. This ensures that
the zero state, which will only be present for a short time, can also be read.
This must be taken into account if the object is being continuously read.
Feature
Description / Value
EDS
Name
EncoderStatusSDO
[MxSubExt40F7]
ParameterName= EncoderStatusSDO
ObjectType=0x7
DataType=0x0005
AccessType=ro
PDOMapping=0
Count=1
Description
Encoder Status SDO
Object Code
ARRAY
Mapping
SDO
Data type
UNSIGNED8
Sub index
01 … FE hex
Access
ro
Byte 0:
Sub index
1
≦
n
≦
254
B7
B6
B5
B4
B3
B2
B1
B0
7
6
5
4
3
2
1
0
–
–
–
Data bit
Desig-
nation
Description
0 – 3
0 = 24VDC OK
1 = 24VDC not OK
4
0 =
1 = Current position is zero position
5
0 = Register has been read
1 = Zero position has been crossed and not yet read.
6 – 7
reserved
Содержание XN-312-GW-CAN
Страница 1: ...Manual CANopen Gateway XN 312 GW CAN 06 16 MN050003 EN ...
Страница 4: ...II ...
Страница 14: ...10 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton com ...
Страница 374: ...9 What Happens If 370 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton eu ...
Страница 388: ...384 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton eu ...