7 Product-specific CAN objects XN300 slice modules
7.24 XN-322-1DCD-B35
Gateway XN-312-GW-CAN 06/16 MN050003-EN
www.eaton.eu
317
Duty cycle of PWM output for LED 1:
t
on
= t
on
LED1 * 180 ns
Period duration: PD = 45.9
μ
s
→
f = 21.8 kHz
Duty cycle of PWM output for LED 2:
t
on
= t
on
LED2 * 1100 ns
Period duration: PD = 2805
μ
s
→
f = 3.56 kHz
7.24.4 Motor Control (Object 0x20E7)
Motor control object 0x20E7 can be used to activate the sequence output
and the status feedback in object 0x30E8
Design of the data bytes:
Data bit
Desig-
nation
Description
Notes
0 – 1
SSI Shift Register Frequency
2
0 = OK
1 = Gray Code Decoding
3
0 = Incremental Encoder Mode
1 = SSI busy (1= busy) (read only)
4
Reserved
5
0 =
1 = Error Reset (1 = clear error) (read,
write)
6
0 =
1 = Start with Sync (1= enable)
7
0 =
1 = Continuous Sensor Read
Feature
Description / Value
EDS
Name
MotorControl
[MxSubExt20E7]
ParameterName=MotorControl
ObjectType=0x7
DataType=0x0006
AccessType=wo
PDOMapping=1
Count=1
Description
Motor Control Register
Object Code
ARRAY
Mapping
PDO
Manual
Data type
UNSIGNED16
Sub index
01 … FE
hex
Access
wo
Default value
0000
hex
Содержание XN-312-GW-CAN
Страница 1: ...Manual CANopen Gateway XN 312 GW CAN 06 16 MN050003 EN ...
Страница 4: ...II ...
Страница 14: ...10 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton com ...
Страница 374: ...9 What Happens If 370 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton eu ...
Страница 388: ...384 Gateway XN 312 GW CAN 06 16 MN050003 EN www eaton eu ...