37
Gentier Real-Time PCR System
Reminding
: when user select the different tab in the operation area, different function
icons will be added accordingly in the tool bar of application software.
Run Setting
tab: when the
Run Setting
tab is selected on the main interface, two additional
function icons will be shown in the tool bar on the run setting interface.
<
Choose Run Parameter Template >
: click this icon in the tool bar and the application
software will automatically pop up choose run parameter template window; user can
choose a saved run parameter template set the current experiment based on the selected
template.
<
Save Run Parameter Template >
: click this icon in the tool bar and the application
software will automatically pop up save run parameter template window; user can choose a
path and save the parameters of current experiment as a template.
▶
Sample Setting
tab: when the
Sample Setting
tab is selected, two additional function icons
will be shown in the tool bar on the sample setting interface.
<
Choose Sample Parameter Template>
: click this icon in the tool bar and the
application software will automatically pop up choose sample parameter template window;
user can choose a saved sample parameter template and set current experiment based on
this template.
<
Save Sample Parameter Template>
: click this icon in tool bar and the application
software will automatically pop up save sample parameter template window; user can
choose a path and save the sample parameters of current experiment as a template.
Analysis
tab: when the
Analysis
tab is selected, four additional function icons will be shown
in the tool bar on the analysis interface.
<
New Analysis>
: after the completion of experiment, user can click this icon in the tool
bar to create a new analysis method based on the current experiment data; the application
software provides user with six analysis methods:
Abs Quant, Rel Quant, Melting Curve,
High Resolution Melting, Genotyping
and
EndPoint Fluorescence
.
<
Analysis Setting >
: after the completion of experiment, user can click this icon in the
tool bar to set the relevant parameters for the current experiment data analysis method.
<
Delete Analysis >
: user can click this icon in the tool bar to delete the selected
analysis method.
<
Export Lis >
: after the completion of experiment, user can click this icon in the tool
bar to export the current experiment data; user can choose the export file format (
.cvs/. txt
/ .xlsx
) from the drop-down list.