UltiMate 3000 Series:
SD, RS, and BM Pumps
Operating Instructions
Page
199
11.3 Consumables and Spare Parts
The part number always refers to the packing unit. Unless otherwise stated, the packing
unit is 1 unit. For more information, contact the Dionex sales organization.
Description
Part No.
Bottle cap (4 caps) for rear seal wash system and solvent reservoirs
(including caps to close the holes in the bottle cap)
6270.0013
Capillaries, set of capillaries for HPG-3x00SD/RS pumps (including fittings),
including:
2 capillaries from working cylinder to equilibration cylinder (U-tubes)
1 capillary from left pump head to purge unit
1 capillary from right pump head to purge unit
6040.3000
Capillaries, set of capillaries for ISO-3100BM pumps
(including fittings), including:
1 capillary from working cylinder to equilibration cylinder (U-tube)
1 capillary from pump head to purge unit
1 capillary from purge unit to pulse damper
1 capillary from pulse damper to inline filter
6042.3002
Capillaries, set of capillaries for ISO-3100SD, LPG-3400SD/RS, and DGP-
3600SD/RS pumps
(including fittings), including:
2 capillaries from working cylinder to equilibration cylinder (U-tubes)
2 capillaries from pump head to purge unit
6040.3001
Capillaries, set of capillaries for LPG-3400BM and DGP-3600BM pumps
(including fittings), including:
2 capillaries from working cylinder to equilibration cylinder (U-tubes)
2 capillaries from pump head to purge unit
2 capillaries from purge unit to inline filter
Note:
The capillary from purge unit to inline filter can be ordered also separately (part
no. 6042.3024).
6042.3001
Capillaries, Viper, for UltiMate 3000 RSLC systems (single stack setup)
Capillary (0.13 x 550 mm (I.D. x L), SST, Viper)
Capillary (0.18 x 450 mm (I.D. x L), SST, Viper)
e.g., for the connection from the LPG-3400RS/DGP-3600RS pump
to the WPS-3000RS
Capillary (0.18 x 550 mm (I.D. x L), SST, Viper)
e.g., for the connection from the HPG-3x00RS pump to the WPS-3000RS
Capillary (0.13 x 350 mm (I.D. x L), SST, Viper)
e.g., for the connection from the WPS-3000RS to the TCC-3000RS (column inlet)
Capillary (0.13 x 250 mm (I.D. x L), SST, Viper)
e.g., for the connection from the TCC-3000RS (column outlet) to the DAD-3000RS,
MWD-3000RS, or VWD-3400RS
Capillary (0.13 x 150 mm (I.D. x L), SST, Viper)
6040.2305
6040.2365
6040.2355
6040.2335
6040.2325
6040.2315
Содержание UltiMate 3000 Series
Страница 2: ...UltiMate 3000 Series SD RS and BM Pumps Operating Instructions ...
Страница 4: ...UltiMate 3000 Series SD RS and BM Pumps Page II Operating Instructions ...
Страница 5: ...UltiMate 3000 Series SD RS and BM Pumps Operating Instructions Page III ...
Страница 6: ...UltiMate 3000 Series SD RS and BM Pumps Page IV Operating Instructions ...
Страница 7: ...UltiMate 3000 Series SD RS and BM Pumps Operating Instructions Page V ...
Страница 8: ...UltiMate 3000 Series SD RS and BM Pumps Page VI Operating Instructions ...
Страница 14: ...UltiMate 3000 Series SD RS and BM Pumps Page vi Operating Instructions ...
Страница 24: ...UltiMate 3000 Series SD RS and BM Pumps Page 10 Operating Instructions ...
Страница 58: ...UltiMate 3000 Series SD RS and BM Pumps Page 44 Operating Instructions ...
Страница 74: ...UltiMate 3000 Series SD RS and BM Pumps Page 60 Operating Instructions ...
Страница 116: ...UltiMate 3000 Series SD RS and BM Pumps Page 102 Operating Instructions ...
Страница 136: ...UltiMate 3000 Series SD RS and BM Pumps Page 122 Operating Instructions ...
Страница 200: ...UltiMate 3000 Series SD RS and BM Pumps Page 186 Operating Instructions ...
Страница 204: ...UltiMate 3000 Series SD RS and BM Pumps Page 190 Operating Instructions ...
Страница 228: ...UltiMate 3000 Series SD RS and BM Pumps Page 214 Operating Instructions ...
Страница 236: ...UltiMate 3000 Series SD RS and BM Pumps Page 222 Operating Instructions ...