![Dell S6000-ON Скачать руководство пользователя страница 1037](http://html.mh-extra.com/html/dell/s6000-on/s6000-on_configuration-manual_845571037.webp)
NOTE: The system reboots when the offline diagnostics complete. This is an automatic
process. The following warning message appears when you implement the
offline stack-
unit
command:
Warning - Diagnostic execution will cause stack-unit to
reboot after completion of diags. Proceed with Offline-Diags [confirm
yes/no]:y
After the system goes offline, you must reload or run the
online stack-unit
stack-unit-number
command for the normal operation.
2.
Confirm the offline status.
EXEC Privilege mode
show system brief
3.
Start diagnostics on the unit.
diag stack-unit
stack-unit-number
When the tests are complete, the system displays the following message and automatically reboots
the unit.
Dell#00:09:42 : Diagnostic test results are stored on file: flash:/
TestReport-SU-0.txt
Diags completed... Rebooting the system now!!!
Mar 12 10:40:35: %S6000:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack
unit 0
Diagnostic results are printed to a file in the flash using the filename format
TestReport-SU-<stack-
unit-id>.txt
.
Log messages differ somewhat when diagnostics are done on a standalone unit and on a stack
member.
4.
View the results of the diagnostic tests.
EXEC Privilege mode
show file flash://TestReport-SU-
stack-unit-id
.txt
Examples of Running Offline Diagnostics
The following example shows the
offline stack-unit
stack-unit-number
command.
Dell#offline stack-unit 1
Warning - offline of unit will bring down all the protocols and
the unit will be operationally down, except for running Diagnostics.
Please make sure that stacking is not configured for Diagnostics execution.
Also reboot/online command is necessary for normal operation after the offline
command is issued.
Proceed with Offline [confirm yes/no]:yes
Dell#Mar 12 10:32:18: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 1 down
- stack unit offline
Mar 12 10:32:18: %STKUNIT0-M:CP %IFMGR-1-DEL_PORT: Removed port: Te 1/1/1-/
1/1/3,1/16/1-1/17/2,1/18/1-1/19/4,1/22/4-1/23/3,1/24/1-1/24/3,1/25/1-1/25/3, Fo
1/4,8,12,15,18,19,20,21,22,23,25,27,29,
The following example shows the
show system brief
command.
Dell#show system brief
Stack MAC : 10:11:12:13:14:15
Reload-Type : normal-reload [Next boot : normal-reload]
Debugging and Diagnostics
1037
Содержание S6000-ON
Страница 1: ...Dell Configuration Guide for the S6000 ON System 9 9 0 0 ...
Страница 505: ...Figure 60 Inspecting Configuration of LAG 10 on ALPHA Link Aggregation Control Protocol LACP 505 ...
Страница 508: ...Figure 62 Inspecting a LAG Port on BRAVO Using the show interface Command 508 Link Aggregation Control Protocol LACP ...
Страница 509: ...Figure 63 Inspecting LAG 10 Using the show interfaces port channel Command Link Aggregation Control Protocol LACP 509 ...
Страница 552: ...mac address table static multicast mac address vlan vlan id output range interface 552 Microsoft Network Load Balancing ...
Страница 557: ...Figure 80 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 557 ...
Страница 558: ...Figure 81 Configuring PIM in Multiple Routing Domains 558 Multicast Source Discovery Protocol MSDP ...
Страница 562: ...Figure 83 MSDP Default Peer Scenario 1 562 Multicast Source Discovery Protocol MSDP ...
Страница 563: ...Figure 84 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 563 ...
Страница 564: ...Figure 85 MSDP Default Peer Scenario 3 564 Multicast Source Discovery Protocol MSDP ...
Страница 665: ...Policy based Routing PBR 665 ...
Страница 672: ...ip pim bsr border Remove candidate RP advertisements clear ip pim rp mapping 672 PIM Sparse Mode PIM SM ...
Страница 818: ...Figure 110 Single and Double Tag TPID Match 818 Service Provider Bridging ...
Страница 819: ...Figure 111 Single and Double Tag First byte TPID Match Service Provider Bridging 819 ...
Страница 995: ...Figure 140 Setup OSPF and Static Routes Virtual Routing and Forwarding VRF 995 ...