Parameters
unit-id
Enter the stack member unit identifier of the stack member
to reset. The range is from 0 to 5 or
all
.
queue size
Enter the queue size of the stack member. The range is from
0 to 5.
Defaults
Not configured
Command
Modes
CONFIGURATION
Command
History
Version 8.3.16.1
Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
You
must
save the configuration and reload the system to implement ASF. When
you enter the command, the system sends a message stating that the new mode is
enabled when the system reloads.
banner exec
Configure a message that is displayed when your enter EXEC mode.
Syntax
banner exec
c line c
Parameters
c
Enter the keywords
banner exec
, then enter a character
delineator, represented here by the letter
c
. Press ENTER.
line
Enter a text string for your banner message ending the
message with your delineator. In the following example, the
delineator is a percent character (%); the banner message is
“testing, testing”.
Defaults
No banner is displayed.
Command
Modes
CONFIGURATION
Command
History
Version 8.3.16.1
Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
Optionally, use the
banner exec
command to create a text string that displays
when you accesses EXEC mode. The
exec-banner
command toggles that display.
Example
Dell(conf)#banner exec ?
LINE c banner-text(max length 255) c, where 'c' is a
delimiting
character
Dell(conf)#banner exec %
Enter TEXT message. End with the character '%'.
This is the banner%
Dell(conf)#end
Dell#exit