Usage
Information
The following example shows the output of the
show environment fan
command as it appears prior to the Dell Networking OS version 7.8.1.0.
Example (all)
Dell#show environment all
-- Unit Environment Status --
Unit Status Temp Voltage
-------------------------------------------
* 0 online 47C ok
* Management Unit
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
Sensor7
Sensor8 Sensor9
---------------------------------------------------------------
-----
----------------
0 50 52 53 53 54 48 57 57
53 56
Dell#
Example
(stack-unit)
Dell#show environment stack-unit 0
-- Unit Environment Status --
Unit Status Temp Voltage
------------------------------------
0* online 49C ok
* Management Unit
Example
(thermal-
sensor)
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
Sensor7
Sensor8 Sensor9
---------------------------------------------------------------
----
----------------
0 50 52 53 53 54 48 57
5753 56
* Management Unit
Dell#
show inventory
Display the switch type, components (including media), and Dell Networking OS version including
hardware identification numbers and configured protocols.
Syntax
show inventory [media
slot
]
Control and Monitoring