INS_CWGE24MS2_REV–
10/05/16 PAGE 259
INSTALLATION AND OPERATION MANUAL
CWGE24MS2
TECH SUPPORT: 1.888.678.9427
CLI Configuration
Node
Command
Description
enable
show snmp user
This command displays all snmp v3 users.
enable
show snmp group
This command displays all snmp v3 groups.
enable
show snmp view
This command displays all snmp v3 view.
configure snmp user USERNAME
GROUPNAME noauth
Configures v3 user of non- authentication.
configure snmp user USERNAME
GROUPNAME auth (MD5|SHA)
STRINGS
Configures v3 user of authentication.
configure snmp user USERNAME
GROUPNAME priv (MD5|SHA)
STRINGS des STRINGS
Configures v3 user of authentication and encryption.
configure snmp group GROUPNAME
noauth (read STRINGS write
STRINGS notify STRINGS)
Configures v3 group of non- authentication.
configure snmp group GROUPNAME auth
(read STRINGS write STRINGS
notify STRINGS)
Configures v3 group of authentication.
configure snmp group GROUPNAME priv
(read STRINGS write STRINGS
notify STRINGS)
Configures v3 group of authentication and encryption.
configure snmp view VIEWNAME STRINGS
(included|excluded)
To identify the subtree.
configure no snmp user USERNAME
GROUPNAME
This command removes a v3 user from switch.
configure no snmp group GROUPNAME
This command removes a v3 group from switch.
configure no snmp view VIEWNAME
STRINGS
This command removes a v3 view from switch.