DS300f G2 Series User Manual
220
Controller was placed on reset during Fail
Over processing
No action is required.
Partner Controller was placed on reset during
Fail Over processing
Controller was reset as it was not able to join
the running partner controller
Verify that the controller is running. If the condition
persists, replace the controller.
The controller has reset because it
encountered a firmware problem
If resets happen frequently, update to new firmware or
replace the controller.
Controller temperature is above the warning
threshold
Check airflow around the
ASUS DS300f G2
. Check
blowers and fans.
The controller temperature is above controller
critical threshold
Controller temperature is within the normal
range
No action is required.
CRC
CRC error is detected while receiving CMD
information unit
If this message appears repeatedly, contact Tech
Support.
CRC error is detected during Data Out phase
Disk Array
New disk array has been created
No action is required.
Disk array has been deleted
Disk array has been added
Disk array has been removed
Disk array settings have been changed
Disk array is transport ready
Remove physical drives in disk array and insert them
into a different subsystem. To cancel Transport Ready
Status, remove and reinsert the drives in their original
slots.
Drive Interface
Drive-interface controller is found
No action is required.
Drive-interface controller is NOT found
Restart the
ASUS DS300f G2
. If this message
appears repeatedly, contact Tech Support.
Drive-interface diagnostics has passed
No action is required.
Drive-interface diagnostics has failed
Restart the
ASUS DS300f G2
. If this message
appears repeatedly, contact Tech Support.
Drive-interface controller has generated a
general parity error
If this message appears repeatedly, contact Tech
Support.
Drive-interface controller has generated a data
parity error
Enclosure
Enclosure temperature is above the threshold
Check blowers and fans.
Enclosure temperature is above the warning
threshold
Check airflow around the
ASUS DS300f G2
. Check
blowers and fans.
Enclosure temperature is above the critical
threshold
Enclosure temperature is within the normal
range
No action is required.
Shut down PSUs due to enclosure or
controller temperature over threshold
Shut down the
ASUS DS300f G2
Event Log
Event logging is enabled
No action is required.
Event logging is disabled
Event log buffer is cleared in RAM
Event log buffer is cleared in NVRAM
Event log buffer is cleared in MDD
Fibre Channel
Fibre Channel controller has detected bus
reset
If this message appears repeatedly, contact Tech
Support.
Fibre Channel controller has received a “LUN
reset” command.
No action is required.
Fibre Channel controller has encountered a
fatal error
Restart the
ASUS DS300f G2
. If this message
appears repeatedly, contact Tech Support.
Fibre Channel link is up
No action is required.
Fibre Channel link is down
Fibre Channel controller settings have
changed
Firmware Update
Firmware update is started
No action is required.
Firmware update is complete
Firmware update is fail
Try the update again. If this message repeats, contact
Tech Support.
Back-end expander firmware upgrade is
started
No action is required.
Back-end expander firmware upgrade is
completed
Back-end expander firmware upgrade failed
Try the update again. If this message repeats, contact
Tech Support.
Front-end expander firmware upgrade is
started
No action is required.
Front-end expander firmware upgrade is
completed
Front-end expander firmware upgrade failed
Try the update again. If this message repeats, contact
Tech Support.
Host Interface
Host interface controller has detected bus
reset
If this message appears repeatedly, contact Tech
Support.
Host interface controller has encountered an
unrecoverable error
Restart the
ASUS DS300f G2
. If this message
appears repeatedly, contact Tech Support.
Host interface controller has received an
“abort task” command.
No action is required.
Host interface controller has received an
“abort task set” command.
Host interface controller has received a “clear
ACA” command.
If this message appears repeatedly, contact Tech