DS300f G2 Series User Manual
147
v
IewInG
I
ScSI t
arGet
I
nformatIon
(clu)
To view information for an iSCSI target:
1. From the Main Menu, highlight
iSCSI Managemen
t and press
Enter
.
2. Highlight iSCSI Targets and press
Enter
.
The list of
iSCSI Targets
displays.
3. Highlight the target you want to change and press
Enter
.
The target information screen displays. Information includes:
•
TargetName
– iSCSI qualified name (iqn) of this target.
•
TargetAlias
– Maximum of 32 characters. Use letters, numbers, space
between words, and underscore. An alias is optional.*
•
TargetStatus
– Up or down.
•
ErrorRecovLevel
– Error recovery level supported.
•
ImmediateData
– Enables the initiator to send unsolicited data with the iSCSI command PDU.
•
MaxConnection
– Maximum number of connections.
•
DataPDUInOrder
– Enables placement of data in PDU order.
•
InitialR2T
– Allows initiator to begin sending data to a target
without receiving a ready to transfer command.
•
DataSeqInOrder
– Enables placement of data in sequential order.
•
OutStandingR2T
– Maximum number of R2T PDUs the target
can have outstanding for a single iSCSI command.
•
MaxBurstLen
– Maximum length of a solicited data sequence in bytes.
•
DefTimeToWait
– After a dropped connection, the number of
seconds to wait before attempting to reconnect.
•
DefTimeToRetain
– Number of seconds after time to wait (above)
before reassigning outstanding commands.
•
HeaderDigest
– Enables the use of header digest (CRC). Enabled or disabled.*
•
DataDigest
– Enables the use of a data digest (CRC). Enabled or disabled.*
•
UniCHAPAuthen
– Uni-directional (peer) CHAP authentication, enabled or disabled.*
•
BiCHAPAuthen
– Bi-directional (local) CHAP authentication, enabled or disabled.*
•
FirstBurstLen
– First burst length in bytes.
•
AssignedPortals
– Portals assigned to this target.
•
NOP-In:
Check iSCSI connection status*
Items marked with an asterisk (*) are adjustable under "Making iSCSI Target Settings (CLU)" on page
m
akInG
I
ScSI t
arGet
S
ettInGS
(clu)
To make target settings:
1. From the Main Menu, highlight
iSCSI Managemen
t and press
Enter
.
2. Highlight
iSCSI Targets
and press
Enter
.
The list of
iSCSI Targets
displays.
3. Highlight the target you want to change and press
Enter
.
The target information screen displays.
4. Highlight
iSCSI Target Settings
and press
Enter
.
5. Make new settings as needed.
• Optional. Highlight
TargetAlias
and type an alias into the field provided.
• Highlight each item and press the Spacebar to toggle between Enable and Disable.
•
HeaderDigest
– Adds a header digest (CRC).
•
DataDigest
– Adds a data digest (CRC).
•
UniCHAPAuthen
– Enables uni-directional CHAP authentication.
•
BiCHAPAuthen
– Enables bi-directional CHAP authentication.
Authentication requires a pre-existing CHAP.
•
Enable NOP-In
- Enable to check iSCSI connection status
6. Highlight
Save Settings
and press
Enter
.
7. Press
Return to Previous Menu
to return to the iSCSI targets list.