DS300f G2 Series User Manual
166
6.
Type the recipient’s IP address into the field provided.
7. Highlight
Message Event Severity Filter
and press the spacebar to change severity levels.
The selected level and all higher severity levels of severity are reported.
See the Table below.
8. Press
Control-A
to save your settings.
Event Severity Levels
Level Description
Fatal
Non-recoverable error or failure has occurred.
Critical
Action is needed now and the implications of the condition are serious.
Major
Action is needed now.
Minor
Action is needed but the condition is not a serious at this time.
Warning
User can decide whether or not action is required.
Information
Information only, no action is required.
d
eleting
n
etsend
r
eciPients
To delete a Netsend recipient:
1. From the Main Menu, highlight
Additional Info and Management
and press
Enter
.
2. Highlight
Software Management
and press
Enter
.
3. Highlight
Netsend
and press
Enter
.
4. Highlight
Message Recipients
and press
Enter
.
5. Highlight the recipient you want to delete and press the spacebar to mark it.
The mark is an asterisk (*) to the left of the listing
6. Highlight
Delete Marked Entries
and press
Enter
.
f
laShInG
throuGh
tftP
Use this function to flash (update) the firmware on the ASUS DS300f G2. See
"Updating with the CLU" on page
v
IewInG
f
lash
I
MaGe
I
nforMatIon
(Clu)
Flash image information refers to the package of firmware components running on your ASUS DS300f G2
controller or controllers.
To view flash image information:
1. From the Main Menu, highlight
Additional Info and Management
, and press
Enter
.
2. Highlight
Flash Image Version Info
and press
Enter
.
The flash image information displays on the screen:
• Enclosure Number – 1 (one) is the Head Unit. Other numbers are cascaded or expanded subsystems
• Running Image Info – Firmware currently running on the controllers
• Flashed Image Info – Firmware flashed to memory
• Image Type – A specific component
• Controller ID – 1 or 2
• Version number
• Build date
• Flash (installation) date
If the Running and Flashed Images do not match, the ASUS DS300f G2 has not restarted since the
firmware was last updated. Restart the ASUS DS300f G2 to run the Flashed firmware package. See
"Restarting a Subsystem" on page <?>
Note that all of these components are upgraded together in a package. See "Updating with the CLU" on
Содержание DS300 G2 Series
Страница 1: ...ASUS Storage DS300 G2 Series ...
Страница 11: ......
Страница 34: ......
Страница 38: ......
Страница 262: ......