DS300f G2 Series User Manual
153
• Highlight
Ping Through Controller ID
and choose a controller (1 or 2)
• Highlight
Ping Through Port ID
and choose a port number (1 to 4)
To change a value, highlight the item, press Backspace to delete the current value and type a new value.
4. Highlight Ping and press
Enter
.
The results of the ping are displayed on the iSCSI Ping screen.
v
IewInG
a
l
ISt
of
I
ScSI t
runkS
(clu)
A trunk is the aggregation of two or more iSCSI ports to increase bandwidth.
To view a list of iSCSI trunks:
1. From the Main Menu, highlight
iSCSI Management
and press
Enter
.
2. Highlight
Trunk
and press
Enter
.
The list of iSCSI Trunks displays.
•
ID
– ID number of the trunk. Starts at 1.
•
CtrlId
– RAID controller ID, 1 or 2
•
Master Port
– One of the four physical ports on the RAID controller
•
Slave Ports
– Any or all of the remaining physical ports on the same RAID controller
•
Failed Ports
– A slave port that has no iSCSI data connection.
•
State
– Optimal, Sub-Optimal or Failed. Identify and correct the failed iSCSI ports.
a
DDInG
I
ScSI t
runkS
(clu)
Ports must be
enabled
to add them to a trunk. See "Making iSCSI Port Settings (CLU)" on page 148. ASUS
DS300f G2 supports a maximum of eight trunks.
You cannot use an iSCSI port that has portals configured to it. See
"Viewing a List of iSCSI Portals (CLU)" on
page 148 and "Deleting iSCSI Portals (CLU)" on page 150.
To add an iSCSI Trunk:
1. From the Main Menu, highlight
iSCSI Management
and press
Enter
.
2. Highlight
Trunk
and press
Enter
.
3. Highlight
Create New Trunk
and press
Enter
.
4.
Enter
information as required:
• Highlight
Controller
and type the controller you want (1 or 2).
• Highlight
Master Port
and type the port number you want (1 to 4).
• Highlight
Slave Ports
and type the port number you want.
For multiple ports, separate the numbers with a comma.
You can choose any or all port numbers except the Master Port number.
5. Highlight
Save Trunk
and press
Enter
.
The new trunk appears in the list.
You can add up to 8 trunks. After you add a trunk, you can assign it to a portal. See"Adding iSCSI Portals
m
akInG
I
ScSI t
runk
S
ettInGS
(clu)
To make trunk settings:
1. From the Main Menu, highlight
iSCSI Management
and press
Enter
.
2. Highlight
Trunk
and press
Enter
.
3. Highlight the trunk you want and press
Enter
.
4.
Enter
information as required:
• Highlight
Controller
and type the controller you want (1 or 2).
• Highlight
Master Port
and type the port number you want (1 to 4).
• Highlight
Slave Ports
and type the port number you want.
For multiple ports, separate the numbers with a comma.
You can choose any or all port numbers except the Master Port number.
5. Highlight
Save Settings
and press
Enter
.
D
eletInG
I
ScSI t
runkS
(clu)
Before you can delete a trunk, you must delete any portals configured on it. See
"Deleting iSCSI Portals (CLU)"
To delete an iSCSI trunk:
1. From the Main Menu, highlight
iSCSI Management
and press
Enter
.
2. Highlight
Trunk
and press
Enter
.
3. Highlight the trunk you want to delete and press the Spacebar to mark it.
4. Highlight
Delete Marked Trunks
and press
Enter
.
5.
Press Y to confirm.