DS300f G2 Series User Manual
119
I
nItIal
C
onneCtIon
Making an initial connection includes the following functions:
•
"Making a Serial Connection" on page 119
•
"Making a SSH Connection" on page 120
•
"Logging Into the CLI" on page 120
•
"Accessing Online Help" on page 121
•
•
"Logging Out of the CLI" on page 121
•
"Logging Back Into the CLI and CLU" on page 121
m
akInG
a
S
erIal
c
onnectIon
Before you begin, be sure the RJ-11-to-DB9 serial data cable is connected between the Host PC and ASUS
DS300f G2, and that both machines are booted and running.
Figure 5 - 1: Serial ports on the controllers (ASUS DS300f G2)
Then do the following actions:
1. Change your
terminal emulation program settings to match the following specifications:
• Bits per second: 115200
• Data bits: 8
• Parity: None
• Stop bits: 1
• Flow control: none
2. Start your PC’s terminal VT100 or ANSI emulation program.
3. Press
Enter
once to launch the CLI.
m
akInG
a
t
elnet
c
onnectIon
A Telnet connection requires a network connection between the Host PC and the Management (Ethernet) port
on the ASUS ASUS DS300f G2 controller.
Figure 5 - 2: Management port on the RAID controller
To start the telnet program:
1. Go to the command line prompt (Windows) or click the terminal icon (Linux).
2. Type
telnet 10.0.0.1
and press
Enter
.
The IP address above is only an example.
Use the Management port IP address of your ASUS DS300f G2.
The Telnet default port number is 2300.
3. Press
Enter
once to launch the CLI.
Содержание DS300 G2 Series
Страница 1: ...ASUS Storage DS300 G2 Series ...
Страница 11: ......
Страница 34: ......
Страница 38: ......
Страница 262: ......