Chapter 5 Detailed Function Introductions
97
Power
off
Operation Freq.
Motor speed
Detect motor's speed and direction
Output voltage
Time
Time
Time
Figure. 5-1-2 Rotating speed tracking restart
Starting process includes the start of inverter power on, power recover, external fault reset, and restart after
coast-to-stop.
Tips:
Speed tracking function only with encoder (PG) or with speed tracking card.
P1.01 Start frequency
Setting range: 0.10~60.00Hz [0.50Hz]
P1.02 Start frequency holding time
Setting range: 0.0~10.0s [0.0s]
Notes:
Start frequency is the initial frequency at which the inverter starts, see f
S
as shown in Figure. 5-1-3 ; Holding time of
starting frequency is the time during which the inverter operates at the starting frequency, see t
1
as shown in Figure.
5-1-3: