![Alpha 6000S series Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/alpha/6000s-series/6000s-series_user-manual_2905269042.webp)
Chapter 3 Operation
41
P0.03 to 12) , the inverter will come into Wobble frequency operation. The Wobble frequency running
parameters can be modified in parameter group P6. By selecting a multi-function terminal and setting the
value to 46, connecting the terminal to terminal “COM”, Wobble frequency operation state can be reset (For
details please see Chapter IV Function of P3)
PLC program timing run: PLC function selection is active (P0.03 = 10), the inverter will select PLC operating
mode, and the inverter will run according to the preset operating mode (see Description of Group P5 function
code). PLC program running can be paused through the function of multi-function terminal 43 (see Chapter
IV Function of P3); PLC halt mode can be reset through the function of multi-function terminal 44 (For
details please see Chapter IV Function of P3);
Normal operation: It is also known as simple open-loop operation mode, including 9 modes, which are
keypad digital setting, terminal AI1, terminals AI2, terminal AI3 (Reserved for 3004GB and below models),
pulse input, serial communication, multi-stage speed and terminal UP/DOWN, slip compensation rate, etc.
3.3.2 Check points before running
To check the inverter and be familiar with the operation, test run can be carried out before running, and the
following points should be checked before running: the wiring of major loop
is correct; terminal screws are
tightened; wiring is correct; short circuit caused by cable breakage should be avoided; load state is correct.
3.3.3 Check points during running
Motor is functioning smoothly; the motor rotates in correct direction; the motor has no abnormal vibration;
acceleration or deceleration operation is smooth; the keypad display is correct.
Running state of this series of inverter switches as shown in Fig. 3-10: