Chapter 5 Detailed Function Introductions
130
5.6 PLC Operating (Group P5)
P5.00 PLC Operating mode
Setting range: 0~2
[
2
]
0: Single cycle 1
1: Single cycle 2 (holding the final value)
2: Continuous operation
Notes:
Single cycle 1
The inverter stops automatically after one cycle of operation and will start when receiving RUN command
again. As shown in Figure. 5-5-1.
T1
T2
T3
T4
T5
T6
T7
运行命令
f1
f2
f3
f4
f5
f6
f7
运行频率(Hz)
时间
Figure. 5-5-1 Stop mode after single cycle of PLC
Single cycle 2 (holding the final value)
The inverter will hold the operating frequency and direction of last step after completing one cycle of
operation. As shown in Figure. 5-5-2
Running frequency (Hz)
Time
Run command