Chapter 3 Operation
35
Table 3-2 Keypad menu
key
Name of key
Key functions
PRG
ESC
Programming/Ex
it
Enter or exit programming mode. In monitoring mode, press PRG/ESC key to
switch to programming mode. First, enter function group, and press ENTER key
to enter function code and function parameters progressively; press PRG/ESC, it
will enter function parameters, then function code, function group, next
monitoring state, exit step by step like this; in case of an inverter failure, switch to
failure display and function group. When giving an alarm, switch to alarm state
and functional group.
ENTER
Enter
Enter the sub-menu, or store parameters during parameter setting.
Digital
encoder
+
-
Up (clockwise)
+
It can increase the function code group number, and function code number or
function code value. In parameter setting mode, LED nixie tube blinking displays
modified bit. If pressing the key, the function code value will increase; in display
state, if the keypad is set to be effective, digital frequency setting, speed PID
setting or analog PID digital setting can be increased through the knob.
Down
(counterclockwise)
-
It can reduce the function code group number, function code number or function
code value. In parameter setting mode, LED nixie tube blinking displays modified
bit. If pressing the key, the function code value will decrease; in display mode, if
the keypad is set to be effective, digital frequency setting, speed PID setting or
analog PID digital setting can be decreased.
> >
Shift key
In edit mode, the modified bit of the set data can be selected;
In monitoring mode, display state parameter can be switchable.
JOG
Jog
In keypad mode, press this key to enter into inching running mode.
RUN
Run
In keypad control mode, the inverter will start running, and a running command
will be given.
Direction switch
key
Press this button to change the direction of rotation. See P0.08 function
description for details.
STOP
RESET
Stop/Reset key
In keypad control mode, the key is used to stop the inverter. Clear the failure and
return to normal state when there is a failure.
3.1.3 Description of LED digitals and indicators
On the inverter keypad there are four digitals seven segments LEDs, 3 unit indicators, 5 status indicators. The four
digitals can display the monitoring object, the function parameter values and the fault code, the warning code. The
three unit indicators have eight combinations, and each combination corresponds to one-unit. The combinations and
their corresponding units are as Figure 3-2
亮
灭
PID
r/min
m/s
%
A
V
Hz
无单位
r/min
m/s
%
A
V
Hz
Hz
r/min
m/s
%
A
V
Hz
A
r/min
m/s
%
A
V
Hz
V
r/min
m/s
%
A
V
Hz
r/min
r/min
m/s
%
A
V
Hz
m/s
r/min
m/s
%
A
V
Hz
%
r/min
m/s
%
A
V
Hz
Figure 3-2 Combinations of unit indicator and their means
The five status indicators are just above the four digitals and the mean of each indicator is shown in table 3-3
No unit
On
Off