Chapter 5 Detailed Function Introductions
138
operating
P6.11 amplitude of oscillation
Setting range: 0.0 ~ 50 % (relative to P 0.02) [0.0 %]
P6.12 step frequency
Setting range: 0.0 ~ fifty % (relative to P6.11) [0.0 %]
P6.13 step time
Setting range: 5~50ms [5ms]
P6.14 Wobble frequency cycle
Setting range: 0.1~999.9s [10.0s]
P6.15 Swing ratio
Setting range: 0.1~10.0 [1.0]
Notes:
P6.09 is used to define the operating frequency before entering wobble frequency operation mode.
P6.10 is used to define the time when the inverter operates at wobble-preset frequency.
P6.11 is used to define the range of wobble operating frequency. The actual value is P0.02
×
P6.11.
P6.14 is used to define a cycle of wobble frequency operation including rising and falling processes.
P6.15.is used to define the swing ratio = rise time / fall time.
P6.16 Random wobble selection
Setting range: 0.1 [0]
P6.17 MAX ratio of random wobble
Setting range: 0.1~10 [10]
P6.18 MIN ratio of random wobble
Setting range: 0.1~10 [0.1]
Notes:
P6.16 is used to select a fixed wobble ratio value defined by P6.15 or a random value between P6.18~P6.17.
Wobble frequency inputs have 2 ways:
Automatic input: If P0.03 is set to 12, and then the frequency will be automatically input during running.
Manual input: If P0.03 is not set to 12, the inverter runs in other ways first, when wobble frequency terminal
inputs, perform wobble frequency in manual input mode. Difference: Compared with automatic input, manual
input eliminates the process of running at preset frequency.
General conditions of wobble frequency operation: step up to preset wobble frequency (P6.09) according to
the default acceleration time, wait for a period of time (P6.10), and run to center frequency of wobble
frequency according to the default acceleration and deceleration time, run in circles according to the preset
wobble frequency amplitude value (P6.11), step frequency (P6.12), step time (P6.13), wobble frequency cycle
(P6.14) and swing ratio (P6.15), then slow down according to the default deceleration time after receiving the
stop command.
When the set frequency is the combination of frequency setting source 1 + frequency setting source 2 , the
center frequency is P0.02 + frequency setting source 2; when the set frequency is not the above combinations,
the center frequency is the value of P0.02. General run procedure at wobble frequency is shown in Fig. 5-6-5.