Chapter 5 Detailed Function Introductions
167
When PF.02 is set as 1, all fault records of PE.00~PE.08 in Group PE will be cleared to facilitate debugging
and fault analysis by the user.
When PF.02 is set as 2, the ex-factory values will be reset (except the operation history records, user
password setting and motor parameters).
When PF.02 is set as 3, the ex-factory values will be reset (except the operation history records and user
password setting).
Tips:
If user forget the setting value of parameters, and do not want to set them one by one, setting PF.02 to 2 can be
used to rapidly restored to defaults, in favor of parameters resetting.
After the historical fault records are cleared or the ex-factory values are reset, PF.02 will be restored to 0
automatically, which means that the corresponding operation has been finished.
PF.03 Parameter copy
Setting range: 0~3 [0]
0: No action
1: Parameters download
2: Parameters upload
3: Download parameters except motor
’
s
Notes:
When PF.03 is set as 0, there is no action.
When PF.03 is set as 1 and all parameters are downloaded, the user-set parameters saved on the keypad will
be copied to the frequency inverter.
When PF.03 is set as 2 and parameters are uploaded, all parameters set by the user will be copied to
EEPROM of the keypad from the frequency inverter.
When PF.03 is set as 3 and non-motor parameters are downloaded, the user-set parameters saved on the
keypad, except the motor parameters, will be copied to the frequency inverter.
Tips:
In the same working conditions, if the function of frequency inverter is applied, parameters set by the user can
be copied quickly to reduce the debugging and maintenance time.
The function of parameter copying is only effective for the keypad with LCD. It will be restored to 0
automatically after copying is finished.
PF.05 Product ID 1
Setting range: 0~9999 [Depending on model]
PF.06 Product ID 2
Setting range: 0~9999 [Depending on model]
PF.07 Product ID 3
Setting range: 0~9999 [Depending on model]
PF.08 Product ID 4
Setting range: 0~9999 [Depending on model]
PF.09 Product series number
Setting range: 0~9999 [Depending on model]
PF.10 Software version number
Setting range: 0.00~99.99 [Depending on model]
PF.11 Non-standard version and serial number
Setting range: 0.000~9.999 [Depending on model]
PF.12 Software identification code
Setting range: 0~9999 [Depending on model]