Chapter 5 Detailed Function Introductions
103
alarm
0: Failure to actuate
1: Slowdown running
P1.23 Rate of deceleration during
instantaneous stop deceleration running
Setting range: 0.00 ~ - maximum frequency [10.00Hz /s]
Notes:
If undervoltage occurs at the time of stopping, it only give an alarm of Uu, at this time, the motor cannot be
started. As shown in Fig. 5-1-8:
If undervoltage occurs during running, it will give an alarm of Uu or Uu1 as shown in Fig. 5-1-8; when Uu
occurs, the pulse will be locked and the inverter will run at 0Hz frequency. Uu will disappear after the
recovery; when Uu1 occurs, the inverter will shut down, if the voltage continues to drop to 300V or less, it
will not be regarded as a fault record or a fault output; it will record fault Uu1 after the recovery.
When the action is selected as 1 after the instantaneous stop alarm, the inverter should run slowly at the
instantaneous stop deceleration speed, if the mains supply recovers during the deceleration, the frequency
should be recovered to the set frequency according to the set acceleration time.
Power 1 ON
OFF
ON
Trip-free
time
Treatment 0 RUN
Treatment 1 RUN
Treatment 2 RUN
Uu1 Uu1 Uu1 ... Recorded
Uu
Zero-speed
Uu1 Uu1 ... Recorded
Uu Uu Not record
Zero-speed
Zero-speed
Power 2 ON
OFF
Trip time
Treatment 0 RUN
Treatment 1 RUN
Treatment 2 RUN
Uu1 Uu1 Uu1 ... Not recorded
Uu
Zero-speed
Uu1 Uu1 ... Not recorded
Uu Uu Not recorded
Zero-speed
Zero-speed
Figure. 5-1-8 Trip-free diagram