![Alpha 6000S series Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/alpha/6000s-series/6000s-series_user-manual_2905269062.webp)
Chapter 4 Parameter Index
61
This page is only for 35R5GB and above models
Functi
on
code
Parameter
LCD display
Setting range
Factor
y
setting
Mo
d.
MOD
BUS
addres
s
P3.00
Mode of terminal
action
Mode of
terminal action
0: Closing is active
1: Open is active (normally
open / normally closed is
unconstrained by this)
0
×
0400
P3.01
X1 terminal
function
X1 terminal
function
0: NULL not defined
1: FWD Forward running
2: REV Reverse running
3: RUN
4: F / R rotation direction
5: HLD self-holding
6: RST reset
7: FC set frequency selection
8: FJOG Forward jog
9: RJOG Reverse jog
10: UP Go up
11: DOWN Go down
12: UP / DOWN reset
13: FRE Free stopping
14: Forced stopping (based on
deceleration time of
abnormal stopping)
15: Stopping process plus DC
braking
16: Acceleration and
deceleration prohibition
17: Inverter run prohibition
18: S1 multi-stage speed 1
19: S2 multi-stage speed 2
20: S3 multi-stage speed 3
21: S4 multi-stage speed 4
22: S5 multi-stage speed 5
23: S6 multi-stage speed 6
24: S7 multi-stage speed 7
25: Command to switch to
terminal control 2
26: SS1 multi-stage speed
27: SS2 multi-stage speed
28: SS3 multi-stage speed
29: SS4 multi-stage speed
30: T1 acceleration and
deceleration time 1
31: T2 acceleration and
deceleration time 2
32: T3 acceleration and
deceleration time 3
33: T4 acceleration and
deceleration time 4
34: TT1 acceleration and
deceleration time
35: TT2 acceleration and
deceleration time
36: Forced stopping normally
closed
1
×
0401
Содержание 6000S series
Страница 1: ......
Страница 74: ...Chapter 4 Parameter Index 73 P6 18 Stochastic swing ratio MIN Stochastic swing ratio MIN 0 1 10 0 0 1 0712...
Страница 221: ......