Chapter 4 Parameter Index
62
This page is only for 35R5GB and above models
Functi
on
code
Parameter
LCD display
Setting range
Factor
y
setting
Mo
d.
MOD
BUS
addres
s
37: EH0 external fault
normally open
38: EH1 external fault
normally closed
39: EI0 external interrupt
normally open
40: EI1 external interrupt
normally closed
41: Stopping state plus DC
braking
(Continued on next page)
P3.02
X2 terminal
function
X2 terminal
function
(Contd.)
42: PLC program input
43: PLC program run pause
44: PLC stopping reset
45: Wobble frequency input
46: Wobble frequency state
reset
47: PID input
48: Switch between speed
mode and torque
mode
49: Timing driven input
50: Counter trigger signal
input
51: Counter reset
52: Actual length reset
53: Timing unit selection
54-74: Reserve
75: Anti-locked rotor
operation command
(reserve)
76: Zero servo command
(reserve)
77: PID output is forced to 0
78: PID integral time reset
79: Command to switch to
keypad control
2
×
0402
P3.03
X3 terminal
function
X3 terminal
function
37
×
0403
P3.04
X4 terminal
function
X4 terminal
function
0~79: ditto.
80: PULSE Pulse input
0
×
0404
P3.05
X5 terminal
function
X5 terminal
function
0~79: ditto.
81: Single-phase tachometer
pulse or biphase
tachometer pulse phase A
pulse input
0
×
0405
P3.06
X6 terminal
function
X6 terminal
function
0~79: ditto.
81: Single-phase tachometer
pulse or two-phase
tachometer pulse phase A
pulse input (input of X5
is active when both X5
and X6 are 81)
82: Biphase speed
0
×
0406