MODBUS
Address
Name
bit
Content
0030H
AO3 Analog Output (V) 0~10.00V corresponding to 0~1000 (Reserved for 3004GB and the below)
0031H
DC Main Bus Voltage
0032H
Output Torque
0033H
Current Rotating Speed
0034H
Set Rotating Speed
0035H
Operating Linear Speed
0036H
Set Linear Speed
0037H
Output Power
0038H
PID Feedback Quantity (% )
0039H
PID Input Quantity (% )
003AH
Set Length
003BH
Actual Length
003CH
External Count Value
003D-003FH
(Reserved)
0040-004AH
Terminal State, 0040H
-
004AH corresponding to BIT0-BITA bit of 002BH in order
004B-00FEH
(Reserved)
List of Modbus Register Addresses:
Function Code Form Parameter
Code(DEC)
Modbus Register Address(HEX)
(Saving Confirmed)
(00FFH)
(Command Data)
(0001H~001FH)
(Monitoring Content)
(0020H~004FH)
P0.00~P0.19
0100H~ 0113H*
P1.00~P1.23
0200H~ 0217H
P2.00~P2.50
0300H~ 0332H
P3.00~P3.36
0400H~ 0424H
P4.00~P4.35
0500H~ 0523H
P5.00~P5.36
0600H~ 0624H
P6.00~P6.18
0700H~ 0712H
P7.00~P7.28
0800H~ 081CH
P8.00~P8.28
0900H~ 091CH
P9.00~P9.21
0A00H~ 0A15H
PA00~PA.30
0B00H~ 0B1EH