Appendix 6 LCD Keyboard Use Instruction
217
Function Code Edition State:
Figure A6-3 Programming Display State of LCD Keypad
Supplement: Special Interface Display
Figure A6-4 LCD Keypad: Special Interface Display and Meaning
A6.2.4 Keypad Operation Method
Like the LED keypad, with the LCD keypad, various operations can be conducted on the frequency inverter.
Examples are followed:
Monitoring Parameter Display Switch
补偿前频率
50.00 Hz
设定
频率
输出
电流
设定
转速
运行
转速
实际
长度
>>
>>
>>
>>
>>
>>
输出
频率
(补偿前)
LED
显示
按键
操作
>>
输出
频率
(实际)
LCD
显示
50.00
50.00
50.00
1440
0.000
补偿后频率
50.00 Hz
输出电流
45.0 A
设定频率
50.00 Hz
运行转速
1440 rpm
设定转速
1440 rpm
实际长度
0.000 m
1440
45.0
Figure A6-5 LCD Keypad: Example of Monitoring Parameter Display Operation
Given Frequency Adjustment for Ordinary Operation (Change the Given Frequency from 50.00Hz into 40.00Hz)
停机
显示
输出
频率
按旋钮自动进入
给定频率修改状
态,单位指示闪
烁显示当前设定
频率
向左旋转一
次设定频率
改变0.01Hz
连续旋转并保
持旋转速率可
使调整步长逐
渐加大到0.10
Hz
步长最大可到1Hz,
到达设定值后,若需
保存当前频率设定
调整完频率后直接
按ENTER键即保存
3s后自动退
出返回初始
显示状态
-
-
-
LCD
显示
按键
操作
-
停止
旋转
补偿前频率
0.00 Hz
设定频率
50.00 Hz
设定频率
49.99 Hz
设定频率
49.50 Hz
设定频率
40.00 Hz
补偿前频率
0.00 Hz
Figure A6-6 LCD Keypad: Set Frequency Adjustment Operation
Pre-compensation
Frequency
50.00 Hz
Function Group: P0
Basic Functions
Function Code: P0.02
Frequency Digital Setting
Frequency Digital Setting
50.00 Hz
Primary
Menu
Secondary
Menu
Tertiary
Menu
Edition State
Stop State Parameter
Display or Operation
State Parameter Display
or Fault Alarm Display
Option Parameter Display
Communication Request Display
Terminal State Display
Frequency Setting 1:01
Keyboard Setting
CALL
Communication Request
Terminal State
Option Name
Parameter Name
and Option Value
Key
Operation
LED
LCD
Output
Frequency
(Before
Compensation)
Output
Frequency
(Actual)
Output
Current
Set
Frequency
Operation
Rotating
Speed
Set
Rotating
Speed
Actual
Length
Pre-compensation
Frequency
50.00 Hz
After-compensation
Frequency
50.00 Hz
Output Current
45.0 A
Set Frequency
50.00 Hz
Operation Rotating
Speed
1440 rpm
Set Rotating Speed
1440 rpm
Actual Length
0.000 m
Stop the
inverter
and
display the
output
frequency
Press the knob to enter
the given frequency
revision state; the unit
indicator is flickering
and displaying the
present set frequency
Turn left once to
change the set
frequency by 0.01Hz
Keep turning and
maintain the rotating
speed to make the
adjustment step length
increase to 0.10Hz
gradually
The step length can reach 1Hz at
the most; after the set values is
reached, if the present frequency
setting has to be saved, press the
key ENTER directly after
frequency adjustment is over.
Stop
turning
Key
Operation
LCD
Pre-compensation
Frequency
0.00 Hz
Set Frequency
50.00 Hz
Set Frequency
49.99 Hz
Set Frequency
49.50 Hz
Set Frequency
40.00 Hz
Pre-compensation
Frequency
0.00 Hz
It will escape 3s