![Alpha 6000S series Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/alpha/6000s-series/6000s-series_user-manual_2905269058.webp)
Chapter 4 Parameter Index
57
P3: Switching value I / O terminal control
This page is only for 3004GB and below models
Function
code
Parameter
LCD display
Setting range
Factory
setting
Modify
MODBUS
address
P3.00
Mode of terminal
action
Mode of
terminal action
0: Closing is active
1: Open is active (normally
open / normally closed is
unconstrained by this)
0
×
0400
P3.01
X1 terminal
function
X1 terminal
function
0: NULL not defined
1: FWD Forward running
2: REV Reverse running
3: RUN
4: F / R rotation direction
5: HLD self-holding
6: RST reset
7: FC set frequency selection
8: FJOG Forward jog
9: RJOG Reverse jog
10: UP Go up
11: DOWN Go down
12: UP / DOWN reset
13: FRE Free stopping
14: Forced stopping (based on
deceleration time of
abnormal stopping)
15: Stopping process plus DC
braking
16: Acceleration and
deceleration prohibition
17: Inverter run prohibition
18: S1 multi-stage speed 1
19: S2 multi-stage speed 2
20: S3 multi-stage speed 3
21: S4 multi-stage speed 4
22: S5 multi-stage speed 5
23: S6 multi-stage speed 6
24: S7 multi-stage speed 7
25: Command to switch to
terminal control 2
26: SS1 multi-stage speed
27: SS2 multi-stage speed
28: SS3 multi-stage speed
29: SS4 multi-stage speed
30: T1 acceleration and
deceleration time 1
31: T2 acceleration and
deceleration time 2
32: T3 acceleration and
deceleration time 3
33: T4 acceleration and
deceleration time 4
34: TT1 acceleration and
deceleration time
35: TT2 acceleration and
deceleration time
36: Forced stopping normally
closed
37: EH0 external fault
1
×
0401
Содержание 6000S series
Страница 1: ......
Страница 74: ...Chapter 4 Parameter Index 73 P6 18 Stochastic swing ratio MIN Stochastic swing ratio MIN 0 1 10 0 0 1 0712...
Страница 221: ......