![Alpha 6000S series Скачать руководство пользователя страница 146](http://html1.mh-extra.com/html/alpha/6000s-series/6000s-series_user-manual_2905269146.webp)
Chapter 5 Detailed Function Introductions
145
P8.20 Zero servo initial frequency
(reserve)
Setting range: 0.00
~
10.00Hz [0.30Hz]
P8.21 Zero servo gain (reserve)
Setting range:1. 0
~
99.99(G5) [1.00]
P8.22Zero servo tolerance (reserve)
Setting range: 0
~
16383 [10]
Notes:
Parameters related to zero-servo are reserved temporarily.
P8.23 Zero-speed Torque Boosting
Setting range: 0.0~50.0% [0.0%]
P8.24 Zero-speed Threshold
Setting range: 0~20% [5%]
Notes:
P8.23 zero-speed torque boosting is to provide the additional output torque at the startup, so the motor can
overcome the static friction and start smoothly when the set torque is small.
The zero-speed threshold setting range corresponds to the 0~20% maximum output frequency.
P8.25 Brake Torque Setting Source
Setting Range: 0~5 [0]
0: consistent with the final setting value of
driving torque calculated with P8.11
1: AI1
2: AI2
3: AI3 (3004GB and the below are reserved)
4: Impulse Input
5: Serial Communications
P8.26 High-speed Torque Make-up Gain
Setting range: 40.0~160.0% [0.0%]
P8.27 High-speed Torque Make-up Base
Setting range: 0~1 [0]
0: Make-up based on the operation frequency
1: Make-up based on the linear speed (Reserved)
Notes:
As the operation speed increases, the mechanical system will consume more and more torque, and the
high-speed torque is to make up for the torque consumed by the mechanical system to keep basically
unchanged the torque gained by the effective load.
What P8.26 sets is the maximum make-up and 100.0% corresponds to the rating output torque of motor.
When the make-up base is “make-up based on the operation frequency”, the relationship between the torque
make-up and the present operation frequency is showed in Figure 5-8-2:
转矩补偿量
最大补偿量
(P8.26)
运行频率(Hz)
最大输出频率
0
Figure 5-8-2 Relationship between the High-speed Torque Make-up and the Output Frequency
P8.28 Pre-excitation Time
Setting Range: 0.00~120.0s [0.5s]
Notes:
The function of pre-excitation is used to establish the magnetic field before the asynchronous motor starts.
The parameter sets the duration time of this process.
Maximum Output
Frequency
Operation Frequency (Hz)
Maximum
Make-up
(P8.26)
Torque Make-up