1
Connect the USB cable between the USB ports available on the front side of
the ESM of chassis with the USB port available on the rear side of J-BERT
N4903B.
2
On connecting both the instruments with USB cable, if the “Found New
Hardware Wizard” appears as shown in the figure, you may need to install the
following drivers:
• USB driver
• AX88178 driver (USB to Ethernet Controller)
3
To install the USB driver, choose “Install the software automatically
(Recommended)” and click "Next" to start installing the device, then click
"Finish" once the wizard completes the process.
4
To install the AX88178 driver, download the latest version of AX88178 driver
from the following webpage: www.asix.com.tw.
After downloading, simply double-click on the .exe file to begin installation. You
will receive a confirmation that the process has begun, and another upon
successful completion.
5
If you do not install the AX88178 driver, you will still be able to use M8061A.
However, in this case the Ethernet port over USB connectivity on the ESM will
not get configured.
N O T E
Agilent recommends you to establish a USB connection between the USB ports of
M8061A and J-BERT N4903B via a powered USB 2.0 hub to prevent the USB port
shutdown due to excessive power drawn by the USB devices connected at the J-
BERT N4903B USB ports.
Connecting M8061A to N4903B Pattern Generator and DUT
After the USB connection has been established, you can connect the M8061A to
the N4903B Pattern Generator and DUT. Follow the given steps:
1
Disable the outputs of the N4903B and use the matched cable kit M8061-61601
to connect the pattern generator to the M8061A. Make sure to connect Data
In 1, Data In 2 and Aux Clk In ports of M8061A to Aux Data Out, Data Out and
Aux Clk Out ports of N4903B, respectively. All the respective ports are present
at the front side of the instruments.
Do not loop-in any other equipment (like N4903B’s Option J20).
2
Mount the SMA 50 Ohm terminations on the unused DATA OUT and AUX DATA
OUT ports of the pattern generator using the SMA to 2.4 mm adapters.
3
Enable the M8061A as described in
Multiplexer with De-emphasis Function” on page 49
that the DUT will not be damaged.
10
Customizing the Instrument
550
Agilent J-BERT N4903B High-Performance Serial BERT
Содержание J-BERT N4903B
Страница 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Страница 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 486: ... Input Timing Setup 2 Input Timing Setup 3 9 Solving Problems 486 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 487: ... Input Timing Setup 4 Input Timing Setup 5 Solving Problems 9 Agilent J BERT N4903B High Performance Serial BERT 487 ...
Страница 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...