9
You can view the details of the selected presets. To do so, either click
View/
Edit Preset
button or double-click the preset. Remember, the details of the
system presets will be in the disable mode.
User presets can be modified. To do so, either click
View/Edit Preset
button
or double-click the preset. System presets can not be modified.
10
If you choose error ratio based on 8B/10B symbol comparison, then use the
drop down list to specify whether you want to show the 8B/10B symbol
comparison results as SER/FER/cBER/FSR/DER/ISR.
N O T E
Two additional error indicators "Symb Lock" and "8b10b Error"will appear at the
lower pane of GUI, if you select the error ratio as "8B/10B Symbol Comparison"
from the
Error Detector - Error Ratio
'
s window. For more details, see
“8b10b Error Indicator” on page 192
N O T E
Depending upon the selection (SER/FER/cBER/FSR/DER/ISR), the
Status
Indicator at the upper pane of the GUI will change. For more details, see
.
N O T E
Depending upon the selection (SER/FER/cBER/FSR/DER/ISR), the
Results sub-
menu will now show either
SER Results/FER Results/cBER Results/FSR Results/
DER Results/ISR Results as instantaneous measurements.
11
Set the symbol alignment mode. You have the following options:
• Select "Automatic" mode to enable automatic alignment. In automatic
mode the conversion factor for SER, ISR, and DER is 10. For FER and FSR,
the automatic conversion factor is the specified block length or if not
specified the expected pattern length including filler symbols.
• Select "Manual" mode to disable the automatic alignment and initiate re-
alignment if alignment is not already done or lost.
• Click
ReAlign
button to re-align the symbols again, in case, if the symbol
alignment is lost.
5
Setting up the Error Detector
188
Agilent J-BERT N4903B High-Performance Serial BERT
Содержание J-BERT N4903B
Страница 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Страница 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 486: ... Input Timing Setup 2 Input Timing Setup 3 9 Solving Problems 486 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 487: ... Input Timing Setup 4 Input Timing Setup 5 Solving Problems 9 Agilent J BERT N4903B High Performance Serial BERT 487 ...
Страница 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...