Interference Channel Setup
Interference Channel Setup - Concepts
The optional Interference Channel module can be plugged into the instrument. For
an introduction please refer to
“Interference Channel” on page 402
.
This module is to be connected between the pattern generator's Data Out port and
the DUT. For installation instructions refer to
“Installing Hardware Options -
The Interference Channel simulates intersymbol interference (ISI). It has backplane
traces that conform to the Nelco 4000-6 FR4 specification.
The trace length can be set. According to the chosen length, the module generates
a reproducible amount of intersymbol interference.
The Interference Channel provides also a sinewave generator and a modulator. If
sinusoidal interference (amplitude modulation) is enabled, a minimum trace length
is used.
Data can be input at P1 or P2 by connecting the pattern generator's Data Out to
P1 or P2, respectively.
The output is meant to be connected to the input of the DUT.
C A U T I O N
The module has golden 2.4 mm connectors. Be sure to use the specific cables or
adapters. Improper connection can damage the module.
Interference Channel Setup - Procedures
To set up the Interference Channel module, click
Interference Channel
from the
Jitter
submenu.
To use the Interference Channel module:
1
Click the checkbox that enables the module.
2
Select a trace (refer to the technical specifications for details)
3
If desired, enable sinusoidal interference.
Jitter Tolerance Tests
8
Agilent J-BERT N4903B High-Performance Serial BERT
431
Содержание J-BERT N4903B
Страница 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Страница 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 486: ... Input Timing Setup 2 Input Timing Setup 3 9 Solving Problems 486 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 487: ... Input Timing Setup 4 Input Timing Setup 5 Solving Problems 9 Agilent J BERT N4903B High Performance Serial BERT 487 ...
Страница 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...