Option/Upgrade for jitter injection. Total jitter can be composed from random,
periodic, sinusoidal, and bounded uncorrelated sources.
• J11, U11
Spread Spectrum Clock (SSC) and residual Spread Spectrum Clock (rSSC)
generation.
• J12, U12
Option/Upgrade for automated jitter tolerance compliance tests. Use this test
to ensure that the jitter tolerance of the device under test complies with a
certain standard.
• J20
User-installable hardware module "Interference Channel" for simulating
intersymbol and sinusoidal interference.
• 003/U03
Option/Upgrade for half-rate clocking with variable duty cycle.
• A02
The symbol error ratio (SER) analysis allows error counting of coded, packetized
and retimed data streams. SATA and USB3 are popular examples of serial bus
standards using retimed loopback mode for receiver tolerance testing. SER
analysis includes the automatic handling of the running disparity of 8B/10B
coded patterns, filtering of up to 4 user-definable filler symbols, filtering without
any dead times up to 11.5 Gb/s data rates (12.5 Gb/s when using analyzer with
external clock), display of the error ratio as SER or calculated BER.
For PCIe3 (PCI
®
Express 3.0), the option A02 enables the error counter to ignore
changes in the length of 128/130 bit coded SKPOS (Skip Ordered Sets). To use
this functionality, N4903B software revision 7.40 or higher is required.
• 002
Option for N4876A 28 Gb/s Multiplexer 2:1, Second Output Channel and
M8061A 28 Gb/s Multiplexer with De-emphasis.
• A03/UA3
Option/Upgrade with analysis of 128b/132b coded patterns. To use option A03
functionality, the N4903B software revision 7.60 or later is required.
To check the options of your Serial BERT, press
About
in the
Help
menu. The
About
dialog shows the installed options.
De-Emphasis Signal Converter
An external optional instrument which is used to convert the output of the pattern
generator to a de-emphasized signal, as required by many standards such as PCI
Planning the Test
1
Agilent J-BERT N4903B High-Performance Serial BERT
15
Содержание J-BERT N4903B
Страница 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Страница 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 486: ... Input Timing Setup 2 Input Timing Setup 3 9 Solving Problems 486 Agilent J BERT N4903B High Performance Serial BERT ...
Страница 487: ... Input Timing Setup 4 Input Timing Setup 5 Solving Problems 9 Agilent J BERT N4903B High Performance Serial BERT 487 ...
Страница 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...