IM CW140-E
7-8
7.3 Ranges and Number of Digits
●
Active/Reactive/Apparent Power Ranges
The active, reactive and apparent power ranges are determined by the
voltage, current ranges and wiring as shown below:
Wiring
Power range
1
φ
2W
Voltage range
×
current range
1
φ
3W
3
φ
3W
Voltage range
×
current range
×
2
3
φ
3Wi
3
φ
4W
Voltage range
×
current range
×
3
●
Range Configuration (Full Scale)
The table below shows active power ranges corresponding to the voltage and
current ranges. Each value in the table is its full scale value.
1
φ
2W
3.000 kW
7.500 kW
15.00 kW
30.00 kW
75.00kW
150.0kW
1
φ
3W
6.000 kW
15.00 kW
30.00 kW
60.00 kW
150.0kW
300.0kW
3
φ
3W
6.000 kW
15.00 kW
30.00 kW
60.00 kW
150.0kW
300.0kW
3
φ
4W
9.000 kW
22.50 kW
45.00 kW
90.00 kW
225.0kW
450.0kW
1
φ
2W
6.000 kW
15.00 kW
30.00 kW
60.00 kW
150.0kW
300.0kW
1
φ
3W
12.00 kW
30.00 kW
60.00 kW
120.0 kW
300.0kW
600.0kW
3
φ
3W
12.00 kW
30.00 kW
60.00 kW
120.0 kW
300.0kW
600.0kW
3
φ
4W
18.00 kW
45.00 kW
90.00 kW
180.0 kW
450.0kW
900.0kW
1
φ
2W
12.00 kW
30.00 kW
60.00 kW
120.0 kW
300.0kW
600.0kW
1
φ
3W
24.00 kW
60.00 kW
120.0 kW
240.0 kW
600.0kW
1200kW
3
φ
3W
24.00 kW
60.00 kW
120.0 kW
240.0 kW
600.0kW
1200kW
3
φ
4W
36.00 kW
90.00 kW
180.0 kW
360.0 kW
900.0kW
1800kW
20.00
50.00
100.0
200.0
500.0
1000
Voltage
range
(V)
Wiring
Current range (A)
Clamp A (20-200A)
150.0
300.0
600.0
Current range for clamp A : 20/50/100/200A
Model : 96030
Current range for clamp C : 50/100/200/500A
Model : 96031
Current range for clamp B : 200/500/1000A
Model : 96032
Clamp C (50-500A)
Clamp B (200-1000A)
TIP
• For reactive and apparent power, the same table applies, however, the units of measurement are
different.
For reactive power: kVar
For apparent power: kVA
• If the VT or PT ratio is set to a value other than 1, multiply each value in the table by the ratio.
Summary of Contents for CW140
Page 1: ...User s Manual CW140 CLAMP ON POWER METER IM CW140 E IM CW140 E 3rd Edition July 2001 YK ...
Page 2: ......
Page 14: ......
Page 72: ......
Page 102: ......
Page 138: ......
Page 152: ......
Page 160: ......
Page 200: ......
Page 256: ......
Page 274: ......
Page 276: ......
Page 286: ......
Page 289: ......