16-1
IM CW140-E
In the Event of a Power Failure
16
Chapter 16. In the Event of a Power Failure
16.1 In the Event of a Power Failure
●
In the Event of a Power Failure (When Powered by AC Adapter)
When the CW140 contains a precharged NiMH battery pack or alkaline
batteries, it automatically changes to battery-driven operation if a power
failure occurs.
When your CW140 does not contain a precharged NiMH battery pack or
alkaline batteries, or if the battery pack or batteries have lost their charge or
have been removed during operation, it saves the following data on battery
back-up memory.
Measurement mode
Task done during continuous measurement
Data saved
Instant mode
Logging
Time of power failure occurrence
Electric energy mode
Integration
Time of power failure occurrence
Integrated values
Demand mode
Demand
Time of power failure occurrence
Total electric energy from start of
demand measurement
Total electric energy during
current demand period
Maximum demand
Time of maximum demand
Harmonics mode
Logging
Time of power failure occurrence
CAUTION
In the event of a power failure occurring when data is being saved or printed, the CW140 immedi-
ately stops printing or saving and the data will be invalid, or in the case of saving data, the file
contents may become corrupt.
Summary of Contents for CW140
Page 1: ...User s Manual CW140 CLAMP ON POWER METER IM CW140 E IM CW140 E 3rd Edition July 2001 YK ...
Page 2: ......
Page 14: ......
Page 72: ......
Page 102: ......
Page 138: ......
Page 152: ......
Page 160: ......
Page 200: ......
Page 256: ......
Page 274: ......
Page 276: ......
Page 286: ......
Page 289: ......