3 - 9
INSP
ADJ
COOLING SYSTEM INSPECTION
3. Inspect:
●
Pressure
Impossible to maintain the specified
pressure for 10 seconds
→
Replace.
EC357002
COOLING SYSTEM INSPECTION
1. Inspect:
●
Coolant level
2. Attach:
●
Radiator cap tester
1
and adapter
2
3. Apply the specified pressure.
NOTE:
●
Do not apply pressure more than specified
pressure.
●
Radiator should be filled fully.
Radiator cap tester:
YU-24460-01/90890-01325
Adapter:
YU-33984/90890-01352
Standard pressure:
180 kPa (1.8 kg/cm
2
, 25.6 psi)
4. Inspect:
●
Pressure
Impossible to maintain the specified
pressure for 10 seconds
→
Repair.
●
Radiator
●
Radiator hose joint
Coolant leakage
→
Repair or replace.
●
Radiator hose
Swelling
→
Replace.