Chapter 4 Periodic Inspection
4-9
4-4
Adjusting and replacing a loose shutter
4-4-1
Replacing the shutter (T6)
Use the following procedure when the T6 shutter must be replaced.
1) Check that the controller power switch is turned off.
2) Remove the 4 screws securing the slider cover and take off the slider cover.
3) Remove the screws securing the shutter.
Remove the 2 screws on the endplate side and the 2 screws on the motor side.
4) Remove the shutter from the shutter guide and pass the new shutter through it.
M3 hex wrench
Endplate
Shutter guide
Shutter