Chapter 2 Installation and Connections
2-16
●
Protective bonding
WARNING
Always ground the robot and controller unit to prevent electrical shock.
Always use the ground terminal (M4 screw) inside the robot unit to make ground connection. The
ground terminal location is shown below. (When you remove the upper and lower covers for the
motor and also the end plate, you will see the ground terminal as shown.)
Ground terminal
Motor upper cover
Motor lower cover
End plate
CAUTION
• A secure ground connection (less than 100-ohm resistance to ground) is recom-
mended.
• Use electrical wire thicker than AWG14 (2mm
2
) as the ground wire.
WARNING
Always turn off the power to the controller before making the ground connection.
Provide a terminal marked “PE” as the protective conductor for the entire system, and connect it
to an external protective conductor. Also securely connect the ground terminal on the robot frame
to the protective conductor.
(Symbol 417-IEC5019)