Chapter 2 Installation and Connections
2-24
M5 or M6 bolt
Installation base
Bolt
Tightening torque
Hex socket-head M5 or M6 bolt, strength: 8.8T,
length: installation base thi 12mm (maximum)
M5: 60kg-cm to 90kg-cm
M6: 100kg-cm to 130kg-cm
●
Protective bonding
WARNING
Always ground the robot and controller unit to prevent electrical shock.
Always use the ground terminal (M4 screw) inside the robot unit to make ground connection. The
ground terminal location is shown below.
Ground terminal (M4 screw)
WARNING
• A secure ground connection (less than 100-ohm resistance to ground) is recom-
mended.
• Use electrical wire thicker than AWG14 (2mm
2
) as the ground wire.