MAINTENANCE
ENGLISH
(1) Plug
(A) ”HIGHEST LEVEL”
(B) ”LOWEST LEVEL”
IMPORTANT:
¡
Connect the charger positive terminal to the
battery positive terminal, and negative to the
negative.
¡
When disconnecting the cable from the battery,
start with the negative terminal first.
When connecting the cable to the battery, start
with the positive terminal first.
If reversed, the contact of tools on the battery may
cause a shortage.
�
Direction for Long Term Storage
1. When storing the generator for long periods of
time, remove the battery, adjust the electrolyte to
the proper level, and store in a dry and dark place.
2. The battery naturally discharges while it is stored.
Recharge it once a month in summer, and every 2
months in winter.
�
Battery Boost Starting
3
DANGER
To avoid serious personal injury.
¡
¡
¡
¡
¡
Battery gases can explode.
Keep cigarettes, sparks, and
flames away from battery.
¡
¡
¡
¡
¡
If generator battery is frozen, do
not battery boost start engine.
¡
¡
¡
¡
¡
DO NOT connect other end of
negative
1
1
1
1
1
jumper cable to
n e g a t i v e
1
1
1
1
1
t e r m i n a l o f
generator battery.
When battery boost starting engine, follow the
instructions below to safely start the engine.
1.
Bring helper battery of the same voltage as
disabled generator within easy cable reach.
2.
Put on safety goggles and rubber gloves.
3.
Ensure the vent caps are securely in place. (if
equipped)
4.
Cover vent caps with damp rags. Do not allow the
rag to touch the battery terminals.
5.
Attach the red clamp to the positive (red,
2
or
pos.) terminal of the dead battery and clamp the
other end of the same cable to the positive (red,
2
or pos.) terminal of the helper battery.
(1) Dead battery
(2) Lay a damp rag over vent caps.
(3) Jumper cables
(4) Engine block or frame
(5) Helper battery
6. Clamp the other cable to the negative (black,
1
or
neg.) terminal of the helper battery.
7. Clamp the other end to the engine block or frame
of the generator as far from the dead battery as
possible.
8. Start the disabled generator.
9. Disconnect the jumper cables in the exact reverse
order of attachment. (Steps 7, 6 and 5).
10. Remove and discard the damp rags.
IMPORTANT:
¡
This machine has a 12 volt negative
1
ground
starting system.
¡
Use only same voltage for jump starting.
¡
Use of a higher voltage source on generators
electrical system could result in severe damage to
generators electrical system.
F-5709
Installation
1. Turn the main switch to the "STOP" position to
prevent an accidental short circuit.
2. Install the battery on the battery mount tray securely.
TIP
Clamp the red wire to the positive (+) terminal and the
black wire to the negative (-) terminal of the battery. Do
not reverse these positions.
IMPORTANT:
¡
Connect the charger positive terminal to the
battery positive terminal, and negative to the
negative.
¡
When disconnecting the cable from the battery,
start with the negative terminal first.
When connecting the cable to the battery, start
with the positive terminal first.
If reversed, the contact of tools on the battery may
cause a shortage.
�
Direction for Long Term Storage
1. When storing the generator for long periods of
time, remove the battery, adjust the electrolyte to
the proper level, and store in a dry and dark place.
2. The battery naturally discharges while it is stored.
Recharge it once a month in summer, and every 2
months in winter.
�
Battery Boost Starting
3
DANGER
To avoid serious personal injury.
¡
¡
¡
¡
¡
Battery gases can explode.
Keep cigarettes, sparks, and
flames away from battery.
¡
¡
¡
¡
¡
If generator battery is frozen, do
not battery boost start engine.
¡
¡
¡
¡
¡
DO NOT connect other end of
negative
1
1
1
1
1
jumper cable to
n e g a t i v e
1
1
1
1
1
t e r m i n a l o f
generator battery.
(1) Plug
(A) "HIGHEST LEVEL"
(B) "LOWEST LEVEL"
9CGNO̲E̲p00-40.indd 50
2009/11/17 16:31:42
34
MAINTENANCE
ENGLISH
(1) Plug
(A) ”HIGHEST LEVEL”
(B) ”LOWEST LEVEL”
IMPORTANT:
¡
Connect the charger positive terminal to the
battery positive terminal, and negative to the
negative.
¡
When disconnecting the cable from the battery,
start with the negative terminal first.
When connecting the cable to the battery, start
with the positive terminal first.
If reversed, the contact of tools on the battery may
cause a shortage.
�
Direction for Long Term Storage
1. When storing the generator for long periods of
time, remove the battery, adjust the electrolyte to
the proper level, and store in a dry and dark place.
2. The battery naturally discharges while it is stored.
Recharge it once a month in summer, and every 2
months in winter.
�
Battery Boost Starting
3
DANGER
To avoid serious personal injury.
¡
¡
¡
¡
¡
Battery gases can explode.
Keep cigarettes, sparks, and
flames away from battery.
¡
¡
¡
¡
¡
If generator battery is frozen, do
not battery boost start engine.
¡
¡
¡
¡
¡
DO NOT connect other end of
negative
1
1
1
1
1
jumper cable to
n e g a t i v e
1
1
1
1
1
t e r m i n a l o f
generator battery.
When battery boost starting engine, follow the
instructions below to safely start the engine.
1.
Bring helper battery of the same voltage as
disabled generator within easy cable reach.
2.
Put on safety goggles and rubber gloves.
3.
Ensure the vent caps are securely in place. (if
equipped)
4.
Cover vent caps with damp rags. Do not allow the
rag to touch the battery terminals.
5.
Attach the red clamp to the positive (red,
2
or
pos.) terminal of the dead battery and clamp the
other end of the same cable to the positive (red,
2
or pos.) terminal of the helper battery.
(1) Dead battery
(2) Lay a damp rag over vent caps.
(3) Jumper cables
(4) Engine block or frame
(5) Helper battery
6. Clamp the other cable to the negative (black,
1
or
neg.) terminal of the helper battery.
7. Clamp the other end to the engine block or frame
of the generator as far from the dead battery as
possible.
8. Start the disabled generator.
9. Disconnect the jumper cables in the exact reverse
order of attachment. (Steps 7, 6 and 5).
10. Remove and discard the damp rags.
IMPORTANT:
¡
This machine has a 12 volt negative
1
ground
starting system.
¡
Use only same voltage for jump starting.
¡
Use of a higher voltage source on generators
electrical system could result in severe damage to
generators electrical system.
F-5709
Installation
1. Turn the main switch to the "STOP" position to
prevent an accidental short circuit.
2. Install the battery on the battery mount tray securely.
TIP
Clamp the red wire to the positive (+) terminal and the
black wire to the negative (-) terminal of the battery. Do
not reverse these positions.
IMPORTANT:
¡
Connect the charger positive terminal to the
battery positive terminal, and negative to the
negative.
¡
When disconnecting the cable from the battery,
start with the negative terminal first.
When connecting the cable to the battery, start
with the positive terminal first.
If reversed, the contact of tools on the battery may
cause a shortage.
�
Direction for Long Term Storage
1. When storing the generator for long periods of
time, remove the battery, adjust the electrolyte to
the proper level, and store in a dry and dark place.
2. The battery naturally discharges while it is stored.
Recharge it once a month in summer, and every 2
months in winter.
�
Battery Boost Starting
3
DANGER
To avoid serious personal injury.
¡
¡
¡
¡
¡
Battery gases can explode.
Keep cigarettes, sparks, and
flames away from battery.
¡
¡
¡
¡
¡
If generator battery is frozen, do
not battery boost start engine.
¡
¡
¡
¡
¡
DO NOT connect other end of
negative
1
1
1
1
1
jumper cable to
n e g a t i v e
1
1
1
1
1
t e r m i n a l o f
generator battery.
(1) Plug
(A) "HIGHEST LEVEL"
(B) "LOWEST LEVEL"
9CGNO̲E̲p00-40.indd 50
2009/11/17 16:31:42
Connectez les câbles
dans l’ordre numérique.
Déconnectez dans l’ordre
inverse après utilisation.
34
MAINTENANCE
(1) Bouchon
(A) « HIGHEST LEVEL »
(B) « LOWEST LEVEL »
Installation
1. Tournez l’interrupteur principal sur la position « STOP »
pour éviter tout court-circuit accidentel.
2. Installez correctement la batterie sur le support de
montage de batterie.
Connectez le câble rouge sur la borne positive (+)
et le câble noir sur la borne négative (-) de la batterie.
N’inversez pas ces positions.
IMPORTANT :
•
Connectez la borne positive du chargeur à la borne
positive de la batterie, et le négatif au négatif.
•
Pour déconnecter le câble de la batterie, commencez
par la borne négative.
Pour connecter le câble à la batterie, commencez par
la borne positive.
Si inversé, le contact d’outils sur la batterie peut
provoquer un court-circuit.
Instructions pour le remisage de longue
durée
1. En vue d’un remisage de longue durée, déposez la
batterie, corrigez le niveau d’électrolyte, et rangez-la
à un endroit sec et sombre.
2. La batterie se décharge naturellement pendant le
remisage. Rechargez-la une fois par mois en été et
tous les 2 mois en hiver.
Démarrage avec batterie de
renforcement
DANGER
Pour éviter de graves blessures :
•
Les gaz de batterie sont explosifs.
Gardez les cigarettes, les étincelles
et les flammes à l’écart de la batterie.
•
Si la batterie du générateur est
gelée, ne faites pas démarrer
le moteur avec une batterie de
renforcement.
•
Ne connectez PAS l’autre extrémité
du câble de pontage négatif
à la borne négative de la
batterie du générateur.
■
■
■
Lorsque vous faites démarrer le moteur avec une batterie
de renforcement, appliquez les instructions ci-dessous
pour faire démarrer le moteur en toute sécurité.
1. Amenez à une distance de câble une batterie auxiliaire
de même tension que le générateur défaillant.
2. Portez des lunettes de sécurité et des gants en
caoutchouc.
3. Veillez à ce que les bouchons d’aération soient
correctement positionnés. (Si équipés.)
4. Couvrez les bouchons d’aération de chiffons pare-
vapeur. Ne laissez pas les chiffons toucher les bornes
de la batterie.
5. Connectez la bague rouge sur la borne positive
(rouge, ou pos.) de la batterie déchargée, et l’autre
extrémité du câble à la borne positive (rouge, ou
pos.) de la batterie auxiliaire.
(1) Batterie déchargée
(2) Posez un chiffon pare-vapeur sur les bouchons d’aération
(3) Câbles de pontage
(4) Bloc moteur ou châssis
(5) Batterie auxiliaire
6. Connectez l’autre câble à la borne négative (noire,
ou nég.) de la batterie auxiliaire.
7. Connectez l’autre extrémité au bloc moteur ou au
châssis du générateur aussi loin que possible de la
batterie déchargée.
8. Faites démarrer le générateur défaillant.
9. Déconnectez les câbles de pontage dans l’ordre
exactement inverse à celui de la connexion. (Etapes
7, 6 et 5)
10. Retirez et éliminez les chiffons pare-vapeur.
IMPORTANT :
•
Cette machine comporte un système de démarrage de
12 volts à la masse négative .
•
Utilisez uniquement la même tension pour le
démarrage avec des câbles.
•
L’utilisation d’une source à haute tension sur le système
électrique du générateur risque d’endommager
gravement le système électrique du générateur.
9CGNO_F.indb 34
2009/12/11 9:41:34
Summary of Contents for EDL13000SDE
Page 2: ...9cg cover_blank indd 1 2009 12 22 10 25 35 ...
Page 66: ...9CGNO E p47 indd 2 9CGNO E p47 indd 2 2009 10 26 10 04 12 2009 10 26 10 04 12 ...
Page 105: ...9CGNO ES p00 40 indd 39 9CGNO ES p00 40 indd 39 2009 12 18 16 57 03 2009 12 18 16 57 03 ...
Page 192: ...Ё 䇁 㒓 9CGNO C p41 46 indd 6 9CGNO C p41 46 indd 6 2009 12 15 17 50 33 2009 12 15 17 50 33 ...
Page 194: ...9CGNO C p47 indd 2 9CGNO C p47 indd 2 2009 12 03 15 34 19 2009 12 03 15 34 19 ...
Page 214: ... SPECIFICATIONS 9CGNO_F indb 4 2009 12 11 9 41 22 ...
Page 230: ...20 FONCTIONNEMENT DU MOTEUR 9CGNO_F indb 20 2009 12 11 9 41 29 ...
Page 250: ...40 DEPANNAGE 9CGNO_F indb 40 2009 12 11 9 41 35 ...
Page 256: ...46 SCHEMA DE CABLAGE 9CGNO_F indb 46 2009 12 11 9 41 37 ...
Page 258: ...9CGNO_F indb 48 2009 12 11 9 41 37 ...
Page 278: ... 1 9CGNO E ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ 9CGNO_R indb 4 2009 12 11 9 50 05 ...
Page 294: ...20 ЭКСПЛУАТАЦИЯ ДВИГАТЕЛЯ 9CGNO_R indb 20 2009 12 11 9 50 13 ...
Page 314: ...40 ПОИСК И УСТРАНЕНИЕ НЕИСПРАВНОСТЕЙ 9CGNO_R indb 40 2009 12 11 9 50 19 ...
Page 320: ...46 МОНТАЖНАЯ СХЕМА 9CGNO_R indb 46 2009 12 11 9 50 21 ...
Page 322: ...9CGNO_R indb 48 2009 12 11 9 50 21 ...
Page 323: ...9CGNO_R indb 48 2009 12 07 17 29 23 ...
Page 325: ... عريب األسالك لشبكة التخطيطى الرسم 46 00AR_9CGN0 indb 46 12 8 2009 9 58 11 AM ...
Page 331: ... عريب وإصالحه اخللل حتري 40 00AR_9CGN0 indb 40 12 8 2009 9 58 07 AM ...
Page 351: ... عريب املحرك تشغيل 20 00AR_9CGN0 indb 20 12 8 2009 9 57 56 AM ...
Page 367: ... عريب املواصفات 4 00AR_9CGN0 indb 4 12 8 2009 9 57 46 AM ...