General Usage Description
DI[15:0]
Input
The dynamic reconfiguration data input (DI) bus provides reconfiguration data.
When not used, all bits must be set to zero.
DWE
Input
The dynamic reconfiguration write enable (DWE) input pin provides the write
enable control signal to write the DI data into the DADDR address. When not used,
it must be tied Low.
DEN
Input
The dynamic reconfiguration enable (DEN) provides the enable control signal to
access the dynamic reconfiguration feature. When the dynamic reconfiguration
feature is not used, DEN must be tied Low.
DCLK
Input
The DCLK signal is the reference clock for the dynamic reconfiguration port.
REL
Input
The release pin is used when the PLL is in PMCD mode. When in PLL mode, leave
unconnected or tied Low. Only use this pin when porting existing Virtex-4 designs
containing the legacy PMCD mode.
CLKOUT[0:5]
(1)
Output
User configurable clock outputs (0 through 5) that can be divided versions of the
VCO phase outputs (user controllable) from 1 (bypassed) to 128. The input clock and
output clocks are phase aligned.
CLKFBOUT
Output
Dedicated PLL feedback output.
CLKOUTDCM[0:5]
(1)
Output
User configurable clocks (0 through 5) that can only connect to the DCM within the
same CMT as the PLL.
CLKFBDCM
Output
PLL feedback used to compensate if the PLL is driving the DCM. If the CLKFBOUT
pin is used for this purpose, the software will automatically map to the correct port.
LOCKED
Output
An output from the PLL that indicates when the PLL has achieved phase alignment
within a predefined window and frequency matching within a predefined PPM
range. The PLL automatically locks after power on, no extra reset is required.
LOCKED will be deasserted if the input clock stops or the phase alignment is
violated (e.g., input clock phase shift). The PLL must be reset after LOCKED is
deasserted.
DO[15:0]
Output
The dynamic reconfiguration output bus provides PLL data output when using
dynamic reconfiguration.
DRDY
Output
The dynamic reconfiguration ready output (DRDY) provides the response to the
DEN signal for the PLLs dynamic reconfiguration feature.
Notes:
1. CLKOUT
N
and CLKOUTDCM
N
are utilizing the same output counters and can not be operated independently.
Table 3-3:
PLL Ports
(Continued)
Pin Name
I/O
Pin Description
Summary of Contents for Virtex-5 FPGA ML561
Page 1: ...Virtex 5 FPGA User Guide UG190 v5 0 June 19 2009 ...
Page 8: ...Virtex 5 FPGA User Guide www xilinx com UG190 v5 0 June 19 2009 ...
Page 20: ...20 www xilinx com Virtex 5 FPGA User Guide UG190 v5 0 June 19 2009 ...
Page 24: ...24 www xilinx com Virtex 5 FPGA User Guide UG190 v5 0 June 19 2009 Preface About This Guide ...
Page 172: ...172 www xilinx com Virtex 5 FPGA User Guide UG190 v5 0 June 19 2009 Chapter 4 Block RAM ...