Protective Elements
Parameter
Description
Setting range
Default
Menu path
t-AR
Supervision
AR Overall supervision time (> sum of all
the timers used by AR)
1.00 - 9999.00s 100.0s
[Protection
Para
/<1..4>
/AR
/General
Settings]
Service Alarm 1 As soon as the AR-Counter exceeds this
number of reclosure attempts an alarm will
be given out (overhauling of the CB)
1 - 65535
1000
[Protection
Para
/<1..4>
/AR
/Wear Monitor]
Service Alarm 2 Too many auto reclosure attempts. If the
parameterized number of AR cycles is
reached, an alarm will be given out.
1 - 65535
65535
[Protection
Para
/<1..4>
/AR
/Wear Monitor]
Max AR/h
Maximum Number of permitted Auto
Reclosure Cycles per hour.
1 - 20
10
[Protection
Para
/<1..4>
/AR
/Wear Monitor]
Initiate AR:
InitiateFc1
Initiate Auto Reclosure : Initiate Function
Start fct
-
[Protection
Para
/<1..4>
/AR
/Shot Manager
/Pre Shot Ctrl]
Initiate AR:
InitiateFc2
Initiate Auto Reclosure : Initiate Function
Start fct
-
[Protection
Para
/<1..4>
/AR
/Shot Manager
/Pre Shot Ctrl]
Initiate AR:
InitiateFc3
Initiate Auto Reclosure : Initiate Function
Start fct
-
[Protection
Para
/<1..4>
/AR
/Shot Manager
/Pre Shot Ctrl]
534
MRI4
DOK-HB-MRI4-2E
Summary of Contents for highprotec MRI4
Page 1: ...Manual Feeder Protection MRI4 Software Version 3 4 a DOK HB MRI4 2E Revision C English...
Page 43: ...Installation and Connection 43 MRI4 DOK HB MRI4 2E...
Page 46: ...Installation and Connection Ensure the correct tightening torques 46 MRI4 DOK HB MRI4 2E...
Page 69: ...Navigation Operation Navigation Operation 69 MRI4 DOK HB MRI4 2E 1 2 3 5 7 6 8 10 9...
Page 353: ...Device Parameters 353 MRI4 DOK HB MRI4 2E...
Page 373: ...373 MRI4 DOK HB MRI4 2E...