Configuration
58
Version 1.0 Rev B - 08/00
System Security
You can control access to the Hopper Plus 120-24 unit with the System Security menu.
Setting Community Names
Community names are used to control SNMP access to the Hopper Plus. Community
Name 1 has read only access, and Community Name 2 has read and write access. Any
SNMP manager can access and configure any Hopper Plus unit on the network as long as
the unit has the correct community names and Ethernet access is enabled (see
Setting
Remote Access
, page 60).
Warning:
Default community names are presented in all Installation and Configuration
guides distributed by Wi-LAN. It is the responsibility of the customer to ensure that
default community names are changed to unique names at installation. Record all
community name changes.
To set community names
1.
From the Main Menu, select
System Security
. The System Security window is
displayed.
2.
Select
SNMP Community Name 1
.
3.
Type in new name.
4.
Press
Enter
. The new name appears in the entry field.
5.
Select
SNMP Community Name 2
.
6.
Type in new name.
7.
Press
Enter
. The new name appears in the entry field.
Community name
Privileges
Default value
SNMP Community Name 1
Read
public
SNMP Community Name 2
Read and Write
netman
System Security
SNMP Community Name 1 -> public
SNMP Community Name 2 netman
Change User Password Press Enter to change password
Confirm User Password Press Enter to confirm password
Change Supervisor Password Press Enter to change password
Confirm Supervisor Password Press Enter to confirm password
Ethernet Access to Local Host on
Wireless Access to Local Host on
Auto Logout Minutes (1-120) 10