Configuration
16
Version 1.0 Rev B - 08/00
Accessing the Main Menu
You can access the Main Menu via the MANAGEMENT port or a
telnet
session.
You can also configure the Hopper Plus 120-24 remotely with the SNMP (Simple
Network Management Protocol) manager. See
Appendix D: SNMP MIB
, page 99 for
information about SNMP.
Accessing Main Menu with MANAGEMENT Port
To access the Main Menu through the MANAGEMENT port
1.
Disconnect the power from the Hopper Plus unit.
2.
Connect a serial cable from a DB9 serial port on the PC to the MANAGEMENT port
on the Hopper Plus (adaptors are shipped with the unit). See
Configuring a Unit as a
Base
, page 10.
3.
Start a terminal emulation program (such as Hyperterm) on the PC. See
Appendix B:
Using HyperTerminal
.
4.
Set the terminal emulation program to emulate a VT100 terminal with the following
settings:
¥
COM port
PC serial port connected to Hopper Plus unit
¥
Bits per second:
9600
¥
Data bits:
8
¥
Parity:
none
¥
Stop bits:
1
¥
Flow control:
none
5.
Reconnect the power to the Hopper Plus unit.
6.
Press
Enter
. The Login menu is displayed.
7.
Type the default password, or type your password.
The Main Menu
is displayed.
Login Account
Default Password
Privileges
User
user
Read Only
Supervisor
supervisor
Read and Write
Wi-LAN Hopper Plus 120-24 Login
Software: Rev 0.0.0 (May 25 2000 10:13:37)
Hardware: Rev 0.0.0 (4MB SDRAM, 4MB Intel Flash)
Enter Password: