Configuration
32
Version 1.0 Rev B - 08/00
RF Station Configuration
The RF Station Configuration menu contains test and optimization parameters for the
Hopper Plus 120-24 unit. You can change the test mode time, operating mode, RF transmit
status, and link monitor period. You can also change Base Station Only settings, and
Remote Station Only settings.
Setting Test Mode Time
Before you test the unit, you need to set the test mode timer. The test mode timer sets the
maximum time that the unit will remain in test mode. If the Hopper Plus is not returned to
the normal mode before time runs out, the unit will perform an automatic software reboot
and return to normal operating mode.
Note:
The timer applies to tests initiated with the configuration menus and the mode
button, but the timer can only be configured via the menus
To set test mode timer
.
1.
From the Main Menu, select
RF Station Configuration
. The RF Station
Configuration window is displayed.
2.
Select
Test Mode Timer Minutes
.
3.
Type the desired time value in minutes (1-1000).
4.
Press
Enter
.
RF Station Configuration
Operating Mode Normal Mode
RF Transmit Status unblocked
Link Monitor Period (0=OFF, 1-10000) 0
Test Mode Timer Minutes (1-1000) -> 5
Base Station Only Parameters
Maximum Remote Distance 5 Km
Link Monitor Remote Station Rank 1
Remote Station Only Parameters
Throttle Enable off
Throttle Level (1-50) 1