Configuration
50
Version 1.0 Rev B - 08/00
Setting System Symmetry Type (Base Station Only)
System symmetry type defines the amount of priority the base unit has when polling the
remotes. The default setting "asymmetric" gives the base unit a time slot after each remote
is polled—an asymmetric system is appropriate when the base is the access point to a large
network.The "symmetric" setting limits the base unit to one time slot for every polling
cycle; a symmetric system is more efficient when the base has data passing requirements
that are similar to the remotes.
To set system symmetry type
1.
From the Main Menu, select
Radio Module Configuration
. The Radio
Module Configuration window is displayed.
2.
Select
System Symmetry Type
.
3.
Scroll to the desired setting as follows.
4.
Press
Enter
.
asymmetric
Base unit higher priority than remotes: the base unit has
one time slot after every remote time slot. This is the default
setting.
symmetric
Base unit the same priority as every remote: the base unit
has one time slot for every polling cycle.
Radio Module Configuration
New Current Flash
Station Type Remote Unit Remote Unit Remote Unit
Station Rank (1-1000) 1 1 1
Center Frequency 2.4400 GHz 2.4400 GHz 2.4400 GHz
Security Password 1 (Hex) 1 1 1
Security Password 2 (Hex) 10 10 10
Security Password 3 (Hex) 100 100 100
Security Password 4 (Hex) 1000 1000 1000
Security Password 5 (Hex) 10000 10000 10000
Scrambling Code (Hex) 0 0 0
Acquisition Code (0-15) 0 0 0
Config Test Minutes (1-120) 30 30 30
Base Station Only Parameters
Repeater Mode off off off
System Symmetry Type -> Asymmetric Asymmetric Asymmetric
Dynamic Polling Level (1-100) 1
Remote Station Only Parameters
Remote Unit RF Group (0-63) 0 0 0
Reboot New RF configuration Press Enter to Execute
Save Current Config to Flash Press Enter to Execute