Radio Module Configuration
Version 1.0 Rev B - 08/00
53
Rebooting and Saving RF Configurations
A reboot is required for temporary changes to the RF configuration to take effect. If the
changes are valid, they can be saved "permanently" in the FLASH memory. If the changes
are not valid, then the old configuration is restored after a programmable time-out.
To reboot new RF configuration
1.
From the Main Menu, select
Radio Module Configuration
. The
Radio
Module Configuration window is displayed.
2.
Select
Reboot New RF Configuration
.
3.
Press
Enter
. The Hopper Plus 120-24 reboots with the new temporary RF
configuration. The old configuration is remains stored in FLASH memory. If the RF
configuration is valid and the unit operates as intended, you can login again, access
the Main Menu, Radio Module Configuration,
Save Current Config to
Flash
to save changes to FLASH memory.
Radio Module Configuration
New Current Flash
Station Type Remote Unit Remote Unit Remote Unit
Station Rank (1-1000) 1 1 1
Center Frequency 2.4400 GHz 2.4400 GHz 2.4400 GHz
Security Password 1 (Hex) 1 1 1
Security Password 2 (Hex) 10 10 10
Security Password 3 (Hex) 100 100 100
Security Password 4 (Hex) 1000 1000 1000
Security Password 5 (Hex) 10000 10000 10000
Scrambling Code (Hex) 0 0 0
Acquisition Code (0-15) 1 1 1
Config Test Minutes (1-120) 30 30 30
Base Station Only Parameters
Repeater Mode off off off
System Symmetry Type Asymmetric Asymmetric Asymmetric
Dynamic Polling Level (1-100) 1
Remote Station Only Parameters
Remote Unit RF Group (0-63) 0 0 0
Reboot New RF configuration -> Press Enter to Execute
Save Current Config to Flash Press Enter to Execute