Setting the Acquisition Code
The acquisition code ensures that the receiver does not process any signals not intended
for that receiver. The receiver processes only signals with the correct acquisition code.
Note:
All units in the same network must have this setting set to the same value.
To set the acquisition code
1.
From the Main Menu, select
Radio Module Configuration
. The Radio
Module Configuration window is displayed.
2.
Select
Acquisition Code
.
3.
Type the Acquisition code (0-15).
4.
Press
Enter
.
Radio Module Configuration
New Current Flash
Station Type Remote Unit Remote Unit Remote Unit
Station Rank (1-1000) 1 1 1
Center Frequency 2.4400 GHz 2.4400 GHz 2.4400 GHz
Security Password 1 (Hex) 1 1 1
Security Password 2 (Hex) 10 10 10
Security Password 3 (Hex) 100 100 100
Security Password 4 (Hex) 1000 1000 1000
Security Password 5 (Hex) 10000 10000 10000
Scrambling Code (Hex) 0 0 0
Acquisition Code (0-15) -> 0 0 0
Config Test Minutes (1-120) 30 30 30
Base Station Only Parameters
Repeater Mode off off off
System Symmetry Type Asymmetric Asymmetric Asymmetric
Dynamic Polling Level (1-100) 1
Remote Station Only Parameters
Remote Unit RF Group (0-63) 0 0 0
Reboot New RF configuration Press Enter to Execute
Save Current Config to Flash Press Enter to Execute