Testing Basic Operation
Version 1.0 Rev B - 08/00
11
4.
Select
Radio Module Configuration
. The Radio Module Configuration
window is displayed.
5.
Select
Station Type
.
6.
Select
Base Unit
and press
Enter
.
7.
Select
Reboot New RF configuration
and press
Enter
. The unit reboots.
8.
Log in to the unit.
9.
Select
Save Current Config to Flash
and press
Enter
. The settings are stored in flash
memory.
10. Select
Logout
from the Main Menu to exit.
Testing Basic Operation
Wi-LAN recommends that you bench test units before placing them the field. You should
first perform a standalone test, then test the bridge as part of a simple network.
Once one unit has been set to a base unit, it can then be used to test all other remote units
without making configuration changes to the remotes.(Units are shipped from factory
configured as remotes).
Performing a Bench Test
To perform a bench test of the bridge
1.
Ensure that you have configured a unit as a base unit.
2.
Ensure that the station type of all other units is
Remote Unit
. See
Setting the Station
Type
, page 42.
Radio Module Configuration
New Current Flash
Station Type -> Remote Unit Remote Unit Remote Unit
Station Rank (1-1000) 1 1 1
Center Frequency 2.4400 GHz 2.4400 GHz 2.4400 GHz
Security Password 1 (Hex) 1 1 1
Security Password 2 (Hex) 10 10 10
Security Password 3 (Hex) 100 100 100
Security Password 4 (Hex) 1000 1000 1000
Security Password 5 (Hex) 10000 10000 10000
Scrambling Code (Hex) 0 0 0
Acquisition Code (0-15) 1 1 1
Config Test Minutes (1-120) 30 30 30
Base Station Only Parameters
Repeater Mode off off off
System Symmetry Type Asymmetric Asymmetric Asymmetric
Dynamic Polling Level (1-100)
Remote Station Only Parameters
Remote Unit RF Group (0-63) 0 0 0
Reboot New RF configuration Press Enter to Execute
Save Current Config to Flash Press Enter to Execute