RF Station Configuration
Version 1.0 Rev B - 08/00
35
Setting the RF Transmit Status
This setting blocks a unit from carrying traffic.
To set RF transmit status
1.
From the Main Menu
,
select
RF Station Configuration
. The RF Station
Configuration window is displayed.
2.
Select
RF Transmit Status
.
3.
Select a setting.
4.
Press
Enter
.
unblocked
Transmits and receives. This is the default setting.
blocked
Receives only
RF Station Configuration
Operating Mode Normal Mode
RF Transmit Status -> unblocked
Link Monitor Period (0=OFF, 1-10000) 0
Test Mode Timer Minutes (1-1000) 5
Base Station Only Parameters
Maximum Remote Distance 5 Km
Link Monitor Remote Station Rank 1
Remote Station Only Parameters
Throttle Enable off
Throttle Level (1-50) 1