
Configuration
44
Version 1.0 Rev B - 08/00
Setting the Center Frequency
The center frequency defines the channel the unit uses to transmit and receive RF energy.
To ensure communication between units, all units in a system must have the same center
frequency value.
To set the center frequency
1.
From the Main Menu, select
Radio Module Configuration
. The Radio
Module Configuration window is displayed.
2.
Select
Center Frequency
.
3.
Scroll to select the RF center frequency to apply to all units in the network.
4.
Press
Enter
. The center frequency is stored in the
New
state.
Radio Module Configuration
New Current Flash
Station Type Remote Unit Remote Unit Remote Unit
Station Rank (1-1000) 1 1 1
Center Frequency -> 2.4400 GHz 2.4400 GHz 2.4400 GHz
Security Password 1 (Hex) 1 1 1
Security Password 2 (Hex) 10 10 10
Security Password 3 (Hex) 100 100 100
Security Password 4 (Hex) 1000 1000 1000
Security Password 5 (Hex) 10000 10000 10000
Scrambling Code (Hex) 0 0 0
Acquisition Code (0-15) 1 1 1
Config Test Minutes (1-120) 30 30 30
Base Station Only Parameters
Repeater Mode off off off
System Symmetry Type Asymmetric Asymmetric Asymmetric
Dynamic Polling Level (1-100) 1
Remote Station Only Parameters
Remote Unit RF Group (0-63) 0 0 0
Reboot New RF configuration Press Enter to Execute
Save Current Config to Flash Press Enter to Execute