Setting Security Passwords
Up to five different passwords can be set for a unit. Only Security Password 1 is required,
the other passwords are optional. The higher the number passwords that are used, the
higher the level of security for the unit. The set of passwords on the remote unit must
match the set of passwords on the base unit. All passwords are exchanged between units,
even when l password are not used. Passwords can be set and modified directly with the
Radio Module Configuration menu.
Note:
All units in the same network must have this setting set to the same value.
To set security passwords
1.
From the Main Menu, select
Radio Module Configuration
. The Radio
Module Configuration window is displayed.
2.
Select
Security Password 1
.
3.
Enter a password in Hex code.
4.
Press
Enter
. The password is stored in the
New
state.
Note:
Security Passwords 2 to 5 are optional.
5.
If you want to use more than one password, select
Security Password
n
.
6.
Enter a password in Hex code.
7.
Select
Reboot New RF configuration
.
8.
Press
Enter
.
The passwords are put into effect.
Radio Module Configuration
New Current Flash
Station Type Remote Unit Remote Unit Remote Unit
Station Rank (1-1000) 1 1 1
Center Frequency -> 2.4400 GHz 2.4400 GHz 2.4400 GHz
Security Password 1 (Hex) 1 1 1
Security Password 2 (Hex) 10 10 10
Security Password 3 (Hex) 100 100 100
Security Password 4 (Hex) 1000 1000 1000
Security Password 5 (Hex) 10000 10000 10000
Scrambling Code (Hex) 0 0 0
Acquisition Code (0-15) 1 1 1
Config Test Minutes (1-120) 30 30 30
Base Station Only Parameters
Repeater Mode off off off
System Symmetry Type Asymmetric Asymmetric Asymmetric
Dynamic Polling Level (1-100) 1
Remote Station Only Parameters
Remote Unit RF Group (0-63) 0 0 0
Reboot New RF configuration Press Enter to Execute
Save Current Config to Flash Press Enter to Execute
All units in the
same network
must have these
configurations
set the same.