Configuration
48
Version 1.0 Rev B - 08/00
Setting Config Test Minutes
Since there is a chance that RF configuration changes will disrupt communications, each
unit returns to its pre-configuration state after a timeout (unless the changes are saved to
FLASH before the timeout). This timeout is set with the Config Test Minutes parameter,
which can be set from 1 to 120 minutes.
When testing, the configuration test timeout value should be set before any other radio
module changes are made, so that the correct value is used if other changes cause the unit
to lock up. If you set the timeout too low, then you may not have time to save the changes
to FLASH. If you set it too high, then you will have to wait a long time for the unit to
reboot after a change that disrupts service.
Note:
All units in the same network must have this setting set to the same value.
To set the test timeout
1.
From the Main Menu, select
Radio Module Configuration
. The Radio
Module Configuration window is displayed.
2.
Select
Config Test Minutes
.
3.
Type the test minutes value (1-120).
4.
Press
Enter
.
5.
Select
Reboot New RF configuration
.
6.
Press
Enter
. The unit reboots with the temporary test timeout period in effect.
7.
To move the setting to FLASH see
Rebooting and Saving RF Configurations
, page 53.
Radio Module Configuration
New Current Flash
Station Type Remote Unit Remote Unit Remote Unit
Station Rank (1-1000) 1 1 1
Center Frequency 2.4400 GHz 2.4400 GHz 2.4400 GHz
Security Password 1 (Hex) 1 1 1
Security Password 2 (Hex) 10 10 10
Security Password 3 (Hex) 100 100 100
Security Password 4 (Hex) 1000 1000 1000
Security Password 5 (Hex) 10000 10000 10000
Scrambling Code (Hex) 0 0 0
Acquisition Code (0-15) 0 0 0
Config Test Minutes (1-120) -> 30 30 30
Base Station Only Parameters
Repeater Mode off off off
System Symmetry Type Asymmetric Asymmetric Asymmetric
Dynamic Polling Level (1-100) 1
Remote Station Only Parameters
Remote Unit RF Group (0-63) 0 0 0
Reboot New RF configuration Press Enter to Execute
Save Current Config to Flash Press Enter to Execute